Filename: tfs 942f.doc
Version 1.0
29.11.2004
VI TELEFILTER
Filter specification
TFS 942F
1/5
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Measurement condition
Ambient temperature:
23
°C
Input power level:
0
dBm
Terminating impedance:
Input:
50
Output:
150 || 82 nH
Characteristics
Remark:
The maximum attenuation in the pass band is defined as the insertion loss ae. The nominal frequency fN is fixed at 942,5 MHz without any tolerance or
limit. The values of absolute attenuation aabs are guaranteed for the whole operating temperature range. The frequency shift of the filter in the operating
temperature range is included in the production tolerance scheme.
tolerance scheme.
D a t a
typ. value
tolerance / limit
Insertion loss
ae
1,8
dB
max.
3,0
dB
Nominal frequency
fN
-
942,5
MHz
Passband
-
fN
±
17,5
MHz
Pass band ripple
0,6
dB
max.
1,5
dB
Absolute attenuation
aabs
0,3
MHz
…
880
MHz
65
dB
min.
50
dB
880
MHz
…
905
MHz
50
dB
min.
35
dB
905
MHz
…
915
MHz
36
dB
min.
20
dB
980
MHz
…
1050
MHz
29
dB
min.
23
dB
1050
MHz
…
3000
MHz
62
dB
min.
50
dB
3000
MHz
…
6000
MHz
51
dB
min.
45
dB
Input VSWR within PB
2,0 : 1
max.
2,3 : 1
Output VSWR within PB
1,9 : 1
max.
2,3 : 1
Phase Imbalance within PB
-
max.
± 5
°
Amplitude Imbalance within PB
-
max.
± 0,5
dB
Input power level
-
max.
15
dBm
Permissible DC voltage
-
max.
5
V
Operating temperature range
OTR
-
- 10 °C ... + 80
°C
Storage temperature range
-
- 40 °C ... + 85
°C
Temperature coefficient of frequency
TCf *
t.b.d.
-
*)
fc(Hz) = Tcf(ppm/K) x (T - TA) x fCTA (MHz)
Generated:
Checked / Approved: