TLE202x, TLE202xA, TLE202xB, TLE202xY
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SLOS191 – FEBRUARY 1997
9
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC+
(see Note 1)
Supply voltage, V
CC–
(see Note 1)
Differential input voltage, V
ID
(see Note 2)
Input voltage range, V
I
(any input, see Note 1)
Input current, I
I
(each input)
Output current, I
O
(each output): TLE2021
20 V
–20 V
±
0.6 V
±
V
CC
±
1 mA
±
20 mA
±
30 mA
±
40 mA
80 mA
80 mA
unlimited
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLE2022
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TLE2024
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Total current out of V
CC–
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Duration of short-circuit current at (or below) 25
°
C (see Note 3)
Continuous total power dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M suffix
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 60 seconds, T
C
: FK package
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, DP, P, or PW package
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package
Total current into V
CC+
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
See Dissipation Rating Table
0
°
C to 70
°
C
–40
°
C to 85
°
C
–55
°
C to 125
°
C
–65
°
C to 150
°
C
260
°
C
260
°
C
300
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . .
. . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential voltages, are with respect to the midpoint between VCC+, and VCC–.
2. Differential voltages are at IN+ with respect to IN–. Excessive current flows if a differential input voltage in excess of approximately
±
600 mV is applied between the inputs unless some limiting resistance is used.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
DERATING FACTOR
ABOVE TA = 25
°
C
5.8 mW/
°
C
4.2 mW/
°
C
8.2 mW/
°
C
11.0 mW/
°
C
11.0 mW/
°
C
8.4 mW/
°
C
9.2 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 85
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D–8
725 mW
464 mW
377 mW
145 mW
DB–8
525 mW
336 mW
—
—
DW–16
1025 mW
656 mW
533 mW
205 mW
FK
1375 mW
880 mW
715 mW
275 mW
J–14
1375 mW
880 mW
715 mW
275 mW
JG–8
1050 mW
672 mW
546 mW
210 mW
N–14
1150 mW
736 mW
598 mW
230 mW
P–8
1000 mW
8.0 mW/
°
C
640 mW
520 mW
200 mW
PW–8
525 mW
4.2 mW/
°
C
336 mW
—
—
recommended operating conditions
C SUFFIX
MIN
±
2
0
I SUFFIX
MIN
±
2
0
M SUFFIX
MIN
±
2
0
UNIT
MAX
±
20
3.5
MAX
±
20
3.2
MAX
±
20
3.2
Supply voltage, VCC
V
Common mode input voltage VIC
Common-mode input voltage, VIC
VCC =
±
5 V
VCC
±
=
±
15 V
V
–15
13.5
–15
13.2
–15
13.2
Operating free-air temperature, TA
0
70
–40
85
–55
125
°
C