co0304_reli-RP1
co0304_reli_e-01
RELIABILITY DATA
This catalog contains the typical specication only due to the limitation of space. When you consider purchase of our products, please check our specication.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
1. Operating Temperature Range
CM-RA/BU-RA Type
25
105
CM-RB Type
TLF9U, TLF14CB
TLF9U :
25
105 , TLF14CB :
25
105
Test method and remarks
Including temperature rise due to self-generated heat.
2. Storage temperature range
CM-RA/BU-RA Type
40
85
CM-RB Type
TLF9U, TLF14CB
3. Rated current
CM-RA/BU-RA Type
Within the specied range
CM-RB Type
TLF9U, TLF14CB
Test method and remarks
CM : The maximum DC value having temperature increase within specied temperature, as detailed in individual specication.
TLF9UA 14CB : The maximum AC value having temperature increase within 45
by the application of AC current.
TLF9UB : The maximum DC value having temperature increase within 45
by the application of DC current.
4. Inductance
CM-RA/BU-RA Type
Within the specied tolerance
CM-RB Type
TLF9U, TLF14CB
Test method and remarks
CM :
Measuring equipment : 4263A (HP) or its equivalent
Measuring frequency : 1kHz
TLF9UA :
Measuring equipment : Impedance analyzer (HP4192A) or its equivalent
Measuring frequency : 1kHz
Measuring voltage
: 0.35Vosc
TLF14CB :
Measuring equipment : LCR meter 4284A or its equivalent
Measuring frequency : 1kHz
Measuring voltage
: 1.0V
5. DC resistance
CM-RA/BU-RA Type
Within the specied tolerance
CM-RB Type
TLF9U, TLF14CB
Test method and remarks
CM TLF : Measuring equipment : DC ohmmeter
6. Terminal strength tensile force
CM-RA/BU-RA Type
No abnormality
CM-RB Type
TLF9U, TLF14CB
Test method and remarks
CM : Fix the component in the direction to draw terminal and gradually apply tensile force as detailed in indiviual specications.
TLF9U : Apply the stated tensile force gradually in the direction to draw terminal.
TLF14CB : Apply the stated tensile force gradually in the direction to draw terminal.
Nominal wire diameter tensile
d [mm]
force [N]
duration [s]
0.6
5
30 5
Nominal wire diameter tensile
d [mm]
force [N]
duration [s]
0.8
10
30 5
7. Temperature rise
CM-RA/BU-RA Type
Refer to individual specication
CM-RB Type
TLF9U, TLF14CB
45
max.
Test method and remarks
TLF : Resistance substitution method
Applied current : Rated current
Duration : 1 hour
8. Insulation resistance between wires
CM-RA/BU-RA Type
100M
min.
CM-RB Type
TLF9U, TLF14CB
Test method and remarks
CM TLF : Applied voltage : Rated voltage (CM-RA/BU-RA, CM-RB
: 500VDC (TLF9UA, 14CB)
: 250VDC (TLF9UB)
Duration : 60sec.