2–7
2.2
Reset and Power-Down Functions
2.2.1
Software and Hardware Reset
The TLV320AIC11 resets the internal counters and registers in response to either of two events:
A low-going reset pulse is applied to terminal RESET
A 1 is written to the programmable-software reset bit (D3 of control register 1)
Either event resets the control registers and clears all the sequential circuits in the device. Reset signals should be
at least 6 master-clock periods long, and it is recommended to synchronize the reset signal with the master clock in
master/slave cascade. For devices in cascade, it takes at least two FS cycles to apply software reset to all devices,
with the master being always programmed last.
2.2.2
Software and Hardware Power Down
With the exception of the digital interface, the device enters the power-down mode when D1 and D2 in control register
3 are set to 1. When PWRDWN is taken low, the entire device is powered down. In either case, the register contents
are preserved and the output of the monitor amplifier is held at the midpoint voltage to minimize pops and clicks.
The amount of power drawn during software power down is higher than it is during a hardware power down because
of the current required to keep the digital interface active. Additional differences between software and hardware
power-down modes are detailed in the following paragraphs. Figure 2–8 represents the internal power-down logic.
PWRDWN
Software Power Down
(For Control Register 3, D1 & D2)
D1 and D2 are
programmed through a
secondary write operation
Internal TLV320AIC11
Figure 2–8. Internal Power-Down Logic
2.2.2.1 Software Power Down
When D1 and D2 of control register 3 are set to 1, TLV320AIC11 enters the software power-down mode. In this state,
the digital-interface circuit is still active, while the internal ADC and DAC channels and differential outputs OUTP and
OUTM are disabled, and DOUT and FSD are inactive. Register data in secondary serial communications is still
accepted, but data in primary serial communications is ignored. The device returns to normal operation when D1 and
D2 of control register 3 are reset.
2.2.2.2 Hardware Power Down
When PWRDWN is held low, the device enters the hardware power-down mode. In this state, the internal-clock
control circuit and the differential outputs OUTP and OUTM are disabled. All other digital I/Os are either disabled, or
remain in the same state they were in immediately before power down. DIN cannot accept any data input. The device
can only be returned to normal operation by taking and holding PWRDWN high. When not holding the device in the
hardware power-down mode, PWRDWN should be tied high.
相关PDF资料
PDF描述
TLV320AIC11I SPECIALTY CONSUMER CIRCUIT, PQFP48
TLV320AIC11CPFB SPECIALTY CONSUMER CIRCUIT, PQFP48
TLV320AIC11IPFB SPECIALTY CONSUMER CIRCUIT, PQFP48
TLV320AIC11CPFBG4 SPECIALTY CONSUMER CIRCUIT, PQFP48
TLV320A11IPFBG4 SPECIALTY CONSUMER CIRCUIT, PQFP48
相关代理商/技术参数
参数描述
TLV320AIC11CPFB 功能描述:接口—CODEC Gen Purp Lo-I/O Vltg 16-Bit 22-KSPS DSP RoHS:否 制造商:Texas Instruments 类型: 分辨率: 转换速率:48 kSPs 接口类型:I2C ADC 数量:2 DAC 数量:4 工作电源电压:1.8 V, 2.1 V, 2.3 V to 5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:DSBGA-81 封装:Reel
TLV320AIC11CPFBG4 功能描述:接口—CODEC 16-BIT D-TYPE LATCH RoHS:否 制造商:Texas Instruments 类型: 分辨率: 转换速率:48 kSPs 接口类型:I2C ADC 数量:2 DAC 数量:4 工作电源电压:1.8 V, 2.1 V, 2.3 V to 5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:DSBGA-81 封装:Reel
TLV320AIC11EVM 功能描述:音频 IC 开发工具 TLV320AIC11 Eval Mod RoHS:否 制造商:Texas Instruments 产品:Evaluation Kits 类型:Audio Amplifiers 工具用于评估:TAS5614L 工作电源电压:12 V to 38 V
TLV320AIC11I 制造商:TI 制造商全称:Texas Instruments 功能描述:General-Purpose Low-Voltage 1.1V to 3.6V/0 16-bit 22-KSPS DSP CODEC
TLV320AIC11IPFB 功能描述:接口—CODEC Gen Purp Lo-I/O Vltg 16-Bit 22-KSPS DSP RoHS:否 制造商:Texas Instruments 类型: 分辨率: 转换速率:48 kSPs 接口类型:I2C ADC 数量:2 DAC 数量:4 工作电源电压:1.8 V, 2.1 V, 2.3 V to 5.5 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:DSBGA-81 封装:Reel