On/Off Control (Standard)
The On/Off Control pin (pin 5) may be used for remote on/off operation. As
shown in Figure 6, the control pin has an internal 10k
pull-up resistor to
approximately 10V. The converter is designed so that it is enabled when the
control pin is left open (normal mode) and disabled when the control pin is
pulled low (to less than +0.8V relative to –Input, pin 2).
Dynamic control of the on/off function is best accomplished with a mechani-
cal relay or an open-collector/open-drain drive circuit (optically isolated if
appropriate). The drive circuit should obviously be able to sink approximately
1mA when activated and withstand more than 10 Volts when deactivated.
Applying an external voltage to pin 5 when no input power is applied to the
converter can cause permanent damage to the converter. The on/off control
function, however, is designed such that the converter can be disabled (pin 5
pulled low) while input power is ramping up and then "released" once the
input has stabilized. Under these circumstances, it takes approximately
30ms for the output of the fully loaded DC/DC to ramp up and settle to within
±1% of its final value after the converter has been turned on.
Synchronization (Optional)
In critical applications employing multiple switching DC/DC converters, it may
be desirable to intentionally synchronize the switching of selected converters
(so the system noise can be reduced with notch filtering) or to purposely
desynchronize the converters (to lessen the current-carrying requirements on
intermediate dc buses). TMP DC/DC Converters have been designed so that
the On/Off Control function on pin 5 can be replaced with a Sync function. This
change has to be implemented by DATEL during the product assembly
process. Contact our Applications Engineering Group for additional details.
To synchronize the switching of multiple TMP converters configured with the
Sync function, an external clock can be applied to pin 5 of each converter.
The clock should be a TTL square wave referenced to –Input (logic high =
+2 to +5 Volts, 250A max.; logic low = 0 to +0.8 Volts, 70A max.) with a
maximum 1sec "high" duration. The frequency of the synchronizing clock
should be higher than that of any individual converter. Therefore, it should be
145kHz ±5kHz.
Output Trimming
The +5V output may be trimmed ±6% via a single external trimpot or fixed
resistor. The trimpot should be connected as shown in Figure 7 with its wiper
connected to pin 10 (Trim). A trimpot can also be used to determine the value
of a single fixed resistor which should be connected as shown in Figure 8.
Connect the resistor between pin 10 (Trim) and pin 9 (+5V Output) to trim
"down" the output voltage. Connect the resistor between pins 10 and 8
(Common) to trim "up" the output voltage. Fixed resistors should be metal-film
types with absolute TCR’s less than 100ppm/°C to ensure stability.
Trim Down
Trim Up
+INPUT
–INPUT
TRIM
COMMON
3
2
9
8
10
LOAD
20k
9
5-10
Turns
+5V OUTPUT
Trim
Down
Trim Up
+INPUT
–INPUT
+5V OUTPUT
TRIM
COMMON
3
2
9
8
10
LOAD
Figure 7. Trim Connections Using a Trimpot
Figure 8. Trim Connections Using Fixed Resistors
DS-0412
4/01
+INPUT
–INPUT
3
2
+10V
10k
9
5
ON/OFF
CONTROL
Figure 6. Driving the On/Off Control Pin
Case Connection
Unlike most other DC/DC converters, TMP DC/DC's do not have their metal
case connected to one of their input pins. The "uncommitted" case is
connected to pin 4 which, depending on your system configuration, should be
connected to either +Input (pin 3) or –Input (pin 2).
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions
contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL,
Inc. trademark.
DATEL (UK) LTD. Tadley, England Tel: (01256)-880444
DATEL S.A.R.L. Montigny Le Bretonneux, France Tel: 01-34-60-01-01
DATEL GmbH München, Germany Tel: 89-544334-0
DATEL KK Tokyo, Japan Tel: 3-3779-1031, Osaka Tel: 6-6354-2025
DATEL, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151
Tel: (508) 339-3000
(800) 233-2765
Fax: (508) 339-6356
Internet: www.datel.com
Email: sales@datel.com
Data Sheet Fax Back: (508) 261-2857
INNOVATION and EXCELLENCE
ISO-9001 REGISTERED
相关PDF资料
PDF描述
TMP-5/5-15/1-Q48-C 3-OUTPUT 30 W DC-DC REG PWR SUPPLY MODULE
TMP-5/5-12/1-D48-C 3-OUTPUT 40 W DC-DC REG PWR SUPPLY MODULE
TMP-5/5-15/1-D24-C 3-OUTPUT 35 W DC-DC REG PWR SUPPLY MODULE
TMR3-4810WI 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
TMR3-4811WI 1-OUTPUT DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
TMP55-D23 制造商:TRUMPOWER 制造商全称:Tumbler Technologies + TRUMPower 功能描述:55 WATT MEDICAL POWER ADAPTERS
TMP55-D24 制造商:TRUMPOWER 制造商全称:Tumbler Technologies + TRUMPower 功能描述:55 WATT MEDICAL POWER ADAPTERS
TMP55-D25 制造商:TRUMPOWER 制造商全称:Tumbler Technologies + TRUMPower 功能描述:55 WATT MEDICAL POWER ADAPTERS
TMP55-S05 制造商:TRUMPOWER 制造商全称:Tumbler Technologies + TRUMPower 功能描述:55 WATT MEDICAL POWER ADAPTERS
TMP55-S06 制造商:TRUMPOWER 制造商全称:Tumbler Technologies + TRUMPower 功能描述:55 WATT MEDICAL POWER ADAPTERS