TMP88CS38/CM38A/CP38A
2005-05-18
88CS38-220
Electrical Characteristics
Absolute Maximum Ratings
(VSS = 0 V)
Parameter
Symbol
Pins
Ratings
Unit
Supply voltage
VDD
0.3 to 6.5
Input voltage
VIN
0.3 to VDD + 0.3
Output voltage
VOUT1
0.3 to VDD + 0.3
V
IOUT1
Ports P2, P3, P4, P5, P64 to P67, P7
3.2
Output current (Per 1 pin)
IOUT2
Ports P60 to P63
30
Σ IOUT1
Ports P2, P3, P4, P5, P64 to P67, P7
120
Output current (Total)
Σ IOUT2
Ports P60 to P63
120
mA
Power dissipation [Topr
= 70°C]
PD
TMP88CS38NG: 600
TMP88CS38FG/
CP38A/CM38A: 400
mW
Soldering temperature (Time)
Tsld
260 (10 s)
Storage temperature
Tstg
55 to 125
Operating temperature
Topr
30 to 70
°C
Note: The absolute maximum ratings are rated values which must not be exceeded during operation,
even for an instant. Any one of the ratings must not be exceeded. If any absolute maximum rating is
exceeded, a device may break down or its performance may be degraded, causing it to catch fire or
explode resulting in injury to the user. Thus, when designing products which include this device,
ensure that no absolute maximum rating value will ever be exceeded.
Recommended Operating Conditions
(VSS = 0 V, Topr = 30 to 70°C)
Parameter
Symbol
Pins
Conditions
Min
Max
Unit
Fc
= 16 MHz NORMAL mode
Fc
= 16 MHz IDLE mode
Supply voltage
VDD
STOP mode
4.5
5.5
VIH1
Except hysteresis input
VDD × 0.70
Input high voltage
VIH2
Hysteresis input
VDD = 4.5 to 5.5V
VDD × 0.75
VDD
VIL1
Except hysteresis input
VDD × 0.30
VIL2
Hysteresis input
VDD = 4.5 to 5.5V
VDD × 0.25
Input low voltage
VIL4
Key-on wakeup input
VDD = 4.5 to 5.5V
0
VDD × 0.65
V
fc
XIN, XOUT
VDD = 4.5 to 5.5V
8.0
16.0
fc
= 8 MHz
8.0
12.0
Clock frequency
fOSC
Internal clock
VDD = 4.5 to 5.5V
fc
= 16 MHz
16.0
24.0
MHz
Note 1: The recommended operating conditions for a device are operating conditions under which it can be
guaranteed that the device will operate as specified. If the device is used under operating conditions
other than the recommended operating conditions (Supply voltage, operating temperature range,
specified AC/DC values etc.), malfunction may occur. Thus, when designing products which include
this device, ensure that the recommended operating conditions for the device are always adhered
to.
Note 2: Clock frequency fc: Supply voltage range is specified in NORMAL mode and IDLE mode.
Note 3: Smaller value is alternatively specified as the maximum value.