DS0214_01
17.05.01
Flexibility & Innovation ….
ELECTRICAL SPECIFICATIONS
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Central Frequency
fo
Nominal
110.592
MHz
3 dB Bandwidth
BW3dB
Nominal
1
MHz
Insertion Loss
ILmin
fo +/- 3.1 MHz
12
dB
Group delay variation
fo ± 500 kHz
300
ns
Rejection ILmin rel.
Rj1
fo - 4.608
… fo – 1.96
MHz
45
dB
Rj2
fo –1.96
… fo – 1.738
MHz
35
dB
Rj3
fo –1.738
… fo – 1.223
MHz
13
dB
Rj4
fo -1.223
… fo - 1.185
MHz
12
dB
Rj5
fo +1.185
… fo +1.223
MHz
12
dB
Rj6
fo +1.223
… fo +1.738
MHz
13
dB
Rj7
fo +1.738
… fo + 1.96
MHz
35
dB
Rj8
fo + 1.96
… fo +4.608
MHz
45
dB
OPERATIONAL ENVIRONMENT
Parameter
Conditions
Min
Typ
Max
Unit
Power Dissipation
Maximum
0
dBm
DC Voltage
Maximum
+10
V
Storage Temperature
-40
+85
°C
Operating Temperature
Operational
-10
+50
°C
TEST REQUIREMENT
Test Item
Condition of Test
Requirements
Shock (Drop Test)
Random free drops 3 times from height of 1.0 meter
onto concrete floor.
Vibration
Total peak amplitude : 1.5 mm
Vibration frequency : 10 to 55 Hz
Sweep period : 1.0 minute
Vibration directions : 3 mutually perpendicular
Duration : 2 hours / direction
The specimens shall meet
the electrical specifications.
Solderability (Solder Heat)
Immersed pad in soldering bath at 245
± 5°C for 5 ±
0.5 seconds.
75% or more of the
immersed surface shall be
covered with solder.
Temperature Characteristics
Specimens shall be measured within -10°C to
+50°C temperature range.
Dry Heat (Aging Test)
Temperature : 125
± 2°C
Duration : 250 hours
Cold Resistance
Temperature : -40
± 3°C
Duration : 96 hours
Thermal Shock
Heat cycle conditions
-55°C
25°C
85°C
(30 min) (5 min) (30 min)
Cycle time : 5 times
The specimen shall meet the
electrical specifications.