参数资料
型号: ULT-12/2.5-D48NM-C
厂商: Murata Power Solutions Inc
文件页数: 5/26页
文件大小: 0K
描述: DC/DC CONVERTER 12V 2.5A 30W
标准包装: 200
系列: ULT
类型: 隔离
输出数: 1
电压 - 输入(最小): 36V
电压 - 输入(最大): 75V
Voltage - Output 1: 12V
电流 - 输出(最大): 2.5A
电源(瓦) - 制造商系列: 30W
电压 - 隔离: 1.5kV(1500V)
特点: 具有远程开/关功能和 UVLO
安装类型: 表面贴装
封装/外壳: 8-SMD 模块,1/32 砖
尺寸/尺寸: 0.92" L x 0.75" W x 0.35" H(23.4mm x 19.1mm x 8.9mm)
包装: 标准包装
工作温度: -40°C ~ 85°C
效率: 91%
电源(瓦特)- 最大: 30W
其它名称: 811-2324-6
ULT Series
Thirty-Second-Brick Isolated DC/DC Converters
with 2:1 Wide Input Range
Performance Speci?cation Notes
? All speci?cations are typical unless noted. Ambient temperature =
+25°Celsius, V IN is nominal, output current is maximum rated nominal.
External output capacitance consists of 400μF capacitors across output
pins; one 33μF low ESR, and three 1μF external input capacitors. All caps
are low ESR.
Testing must be kept short enough that the converter does not appreciably
heat up during testing. For extended testing, use plenty of air?ow. See
derating curves for temperature performance. All models are stable and
regulate within spec without external cacacitance.
? Input Ripple Current is tested and speci?ed over a 5-20 MHz bandwidth
? Regulation speci?cations describe the deviation as the input line voltage
or output load current is varied from a nominal midpoint value to either
extreme (50% load).
? Do not exceed maximum power ratings, sense limits or output overvoltage
when adjusting output trim values.
? Output overload protection is non-latching. When the output overload
is removed, the output will automatically recover.
? All models are fully operational and meet published speci?cations,
including “cold start” at –40°C.
and uses a special set of external ?lters only for the Ripple Current speci-
?cations. Input ?ltering is C IN = 33 μF, C BUS = 220 μF, L BUS = 12?μH. Use
capacitor rated voltages which are twice the maximum expected voltage.
Capacitors must accept high speed AC switching currents.
? Note that Maximum Current Derating Curves indicate an average current
at nominal input voltage. At higher temperatures and/or lower air?ow, the
converter will tolerate brief full current outputs if the average RMS current
over time does not exceed the Derating curve. All Derating curves are
presented at sea level altitude. Be aware of reduced power dissipation
with increasing density altitude.
? Mean Time Before Failure (MTBF) is calculated using the Telcordia (Bel-
core) SR-332 Method 1, Case 3, Issue 1, ground ?xed conditions. Operat-
ing temperature = +25°C, full output load, natural air convection.
? The output may be shorted to ground inde?nitely with no damage. The
Output Short Circuit Current shown in the speci?cations is an average con-
sisting of very short bursts of full rated current to test whether the output
circuit can be repowered.
? The On/Off pin allows the converter to be turned on or off by an external
device such as a switch, a transistor, a logic gate, or an optical isolator.
If the “logic pin” is left ?oating the measured voltage will be outside the
limit's in the data sheet. Those numbers de?ne the levels needed for the
11
12
13
14
15
The converter will shut off if the input falls below the undervoltage thresh-
old. It will not restart until the input exceeds the Input Start Up Voltage.
Output noise may be further reduced by installing an external ?lter. See
the Application Notes. Use only as much output ?ltering as needed and no
more . Larger caps (especially low-ESR ceramic types) may slow transient
response or degrade dynamic performance. Thoroughly test your applica-
tion with all components installed.
If reverse polarity is accidentally applied to the input, always connect an
external fast blow input fuse in series with the +V IN input.
Although extremely unlikely, failure of the internal components of this
product may expose external application circuits to dangerous voltages,
currents, temperatures or power levels. Please thoroughly verify all ap-
plications before committing them to service. Be sure to include appropri-
ately rated FUSES (see speci?cations and Application Notes) to reduce the
risk of failure.
Special care should be exercised so that Input Voltage Transient does not
exceed speci?ed Max 100V/100ms. At normal input a large transient spike
can be generated as a result of distribution inductance and high inrush
current charging input cap on converter. This can be eliminated with 33μF
electrolytic capacitor mounted close to Converter input. The series resis-
tance (500mΩ < ESR < 700mΩ) is essential in this solution.
“control function” to take place and do not represent the voltage that may
be present on the logic pin.
www.murata-ps.com/support
MDC_ULT Series.F01 Page 5 of 26
相关PDF资料
PDF描述
OSTTS09115B CONN TERM BLK PLUG 9POS 3.5MM
OSTHW09B050 CONN TERM BLK PLUG 9POS 2.5MM
NDS6D2412C CONVERT DC/DC 6W 24-12V DUAL T/H
OSTOQ203550 CONN TERM BLK HDR 20POS 3.81MM
OSTOQ203551 CONN TERM BLK HDR 20POS 3.81MM
相关代理商/技术参数
参数描述
ULT-130 制造商:AIMCO 功能描述:Pulse Tool Pneumatic
ULT-130(098T5) 制造商:AIMCO 功能描述:ULT-130 LH Rotation Pulse
ULT-150 制造商:AIMCO 功能描述:Pulse Tool Pneumatic
ULT-150L 制造商:AIMCO 功能描述:Pistol Pulse Tool 3/4 Sq Dr
ULT-180 制造商:AIMCO 功能描述:Pulse Shut Off Tool