参数资料
型号: VI-ARMB-M2N
元件分类: 电源模块
英文描述: 1-OUTPUT 750 W AC-DC UNREG PWR SUPPLY MODULE
文件页数: 11/11页
文件大小: 705K
代理商: VI-ARMB-M2N
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
ARM, Autoranging Rectifier Module
Rev. 3.9
Page 9 of 11
Set your site on VICOR at vicorpower.com
Operating Power (W)
P-P
Ripple
V
olta
g
e
(V
ac)
0
5
10
15
20
25
30
1500
1250
1000
750
500
250
*
2,200
μF
1,600
μF
1,300
μF
*
1,100
μF
820
μF
680
μF (VI-ARM-x1)
(VI-ARMB-x2)
Figure 17 — Ripple voltage vs. operating power and bus
capacitance, series combination of C1, C2 (see Fig. 10)
APPLICATION NOTE (CONT.)
Output Voltage
Ripple
Rejection
(dB)
40
45
50
55
60
65
70
75
80
50
30
15
5
2
Figure 18 — Converter ripple rejection vs. output voltage (typical)
Example
In this example, the output required at the point of load is 12
Vdc at 320 W. Therefore, the output power from the ARM
would be 375 W (assuming a converter efficiency of 85%). The
desired hold-up time is 9 ms over an input range of 90 to 264 Vac.
Determining Required Capacitance for Power Fail
Warning.
Fig. 15 is used to determine hold-up capacitance
for a given power fail warning time and power level, and
shows that the total bus capacitance must be at least 820 F.
Since two capacitors are used in series, each capacitor must
be at least 1,640 F.
Note:
The warning time is not dependent on line voltage. A
hold-up capacitor calculator is available on the Vicor website,
at vicorpower.com/hubcalc.
Determining Ride-through Time.
Figure 16 illustrates ride-
through time as a function of line voltage and output power,
and shows that at a nominal line of 115 Vac, ride-through
would be 68 ms. Ride-through time is a function of line
voltage.
Determining Ripple Voltage on the Hold-up Capacitors.
Fig. 17 is used to determine ripple voltage as a function of
operating power and bus capacitance, and shows that the
ripple voltage across the hold-up capacitors will be 12 Vac.
Determining the Ripple on the Output of the
DC-DC Converter.
Fig. 18 is used to determine the ripple
rejection of the DC-DC converter and indicates a ripple
rejection of approximately 60 dB for a 12 Volt output. If the
ripple on the bus voltage is 12 Vac and the ripple rejection of
the converter is 60 dB, the output ripple of the converter due
to ripple on its input (primarily 120 Hz) will be 12 mV p-p.
Note that Maxi, Mini, Micro converters have greater ripple
rejection then either VI-200s or VI-J00s.
For more information about designing an autoranging AC
input power supply using the ARM and Vicor DC-DC
converter modules, contact Vicor Applications Engineering at
the nearest Vicor Technical Support Center (see back cover),
or send an E-mail to apps@vicorpower.com.
Another consideration in hold-up capacitor selection is their
ripple current rating. The capacitors’ rating must be higher
than the maximum operating ripple current. The approximate
operating ripple current (rms) is given by:
I rms = 2P/Vac
(6)
Where: P = operating power level
Vac = operating line voltage
Calculated values of bus capacitance for various hold-up time,
ride-through time, and ripple voltage requirements are given
as a function of operating power level in Figures 15, 16, and
17, respectively.
相关PDF资料
PDF描述
V375C12C150AN 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
V24A24C400AL3 1-OUTPUT 400 W DC-DC REG PWR SUPPLY MODULE
V24A15H400AN3 1-OUTPUT 400 W DC-DC REG PWR SUPPLY MODULE
V375C12M150AS2 1-OUTPUT 150 W DC-DC REG PWR SUPPLY MODULE
V24A28T400AN2 1-OUTPUT 400 W DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
VI-ARM-C11 制造商:Vicor Corporation 功能描述:VI-ARM Series 500/1000W 20C to +100C Autoranging Rectifier Modules
VIARMC12 制造商: 功能描述:
VI-ARM-C12 制造商:VICOR 制造商全称:Vicor Corporation 功能描述:Autoranging Rectifier Modules Up to 1500 Watts
VI-ARM-C1F3 制造商:Vicor Corporation 功能描述:VI-ARM Series AC front end module
VI-ARM-C1N 制造商:VICOR 制造商全称:Vicor Corporation 功能描述:Autoranging Rectifier Modules Up to 1500 Watts