参数资料
型号: VPS410-G
厂商: Fluke Electronics
文件页数: 3/8页
文件大小: 0K
描述: VOLTAGE PROBE SET 10:1 GREY
标准包装: 1
系列: ScopeMeter® 190 II
类型: 电压探头
衰减值: 10:1
带宽: 300MHz
电阻 - 输入: 1M
电压 - 最大: CAT III 1000V,CAT IV 600V
颜色:
包括: 带夹接地引线,钩夹,测试探头
其它名称: 614-1180
Automatic capture of 100 screens
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is
seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on
glitches or intermittent anomalies an d will operate in “baby-sit” mode capturing 100 specified events
Replay
Replay storage
Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual
control. Each screen has date and time-stamp
Two sets of 100 screens each can be saved internally for later recall and analysis
Direct storage of additional sets on external flash memory drive through USB host port
FFT – frequency spectrum analysis
Shows frequency content of oscilloscope waveform using Fast Fourier Transform
Window
Automatic window
Vertical scale
Frequency axis
Automatic, Hamming, Hanning or None
Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Linear / Logarithmic (in volts or amps)
Frequency range automatically set as a function of timebase range of oscilloscope
Waveform compare and pass/fa il testing
Waveform Compare
Pass/Fail Testing
Provides storage and display of a reference waveform for visual comparison with newly acquired
waveforms. Reference is derived from an acquired waveform and can be modified in the ScopeMeter
In waveform compare mode, the ScopeMeter can be set up to store only matching (“Pass”) or only
non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis
Automatic scope measurements
Vdc, Vac rms, Vac+dc, Vpeak max, Vpeak min, Vpeak to peak, Aac, Adc, Aac+dc, frequency (in Hz), risetime (using cursors), falltime (using
cursors), phase (between any 2 inputs), pulsewidth (pos./neg.), dutycycle (pos./neg.), temperature °C, temperature °F (not for Japan), dBV, dBm
into 50 Ω and 600 Ω
Advanced power and motor drive
functions
Advanced functions
Cursor measurements
Source
Dual horizontal lines
Dual vertical lines
Single vertical line
ZOOM
V/Hz ratio (190-x02 only), Power Factor (PF), Watts, VA, VA reactive, V PWM ac and V PWM (ac+dc) for
measurement on pulsewidth modulated motordrives and frequency inverters
mA*s (current-over-time, between cursors);
V*s (voltage over time, between cursors);
W*s (energy, between cursors)
On any input waveform or on mathematical resultant waveform (excl. X-Y-mode)
Voltage at cursor 1 and at cursor 2, voltage between cursors
Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers,
falltime with markers; Vrms between cursors, Watts between cursors
Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency
component in the FFT Resultant
Ranges from full record overview to zoom in up to sample level, at any record length
ScopeMeter 190 Series II
Fluke Corporation 3
相关PDF资料
PDF描述
VPS410-B VOLTAGE PROBE SET 10:1 BLUE
CWX823-015.36M OSC 15.3600MHZ 3.3V +-50PPM SMD
FSB50550TB2 MODULE SPM 500V 1.2A SPM23
VPS410-R VOLTAGE PROBE SET 10:1 RED
5827A PROBE OSCILLOSCOPE 200 MHZ X100
相关代理商/技术参数
参数描述
VPS410-II-R 制造商:Fluke Electronics 功能描述:INDUS.VOLT.PROBE SET 500MHZ 10:1 RED
VPS410-R 功能描述:测试探头 Voltage probe set 10:1 red 190 Series RoHS:否 制造商:Teledyne LeCroy 设备类型:Passive Probes 带宽:500 MHz 尖端类型: 长度:1.3 mm 颜色:Black 电压额定值: 电流额定值:
VPS410-V 功能描述:测试探头 Voltage probe set 10:1 grn 190 Series RoHS:否 制造商:Teledyne LeCroy 设备类型:Passive Probes 带宽:500 MHz 尖端类型: 长度:1.3 mm 颜色:Black 电压额定值: 电流额定值:
VPS420-R 功能描述:测试探头 High working voltage 100:1 190 Series II RoHS:否 制造商:Teledyne LeCroy 设备类型:Passive Probes 带宽:500 MHz 尖端类型: 长度:1.3 mm 颜色:Black 电压额定值: 电流额定值:
VPS4C06B10 制造商:Hamlin Electronics 功能描述: