LSR[1]: Receiver Overrun Flag
Logic 0 = No overrun error (default).
Logic 1 = Overrun error. A data overrun error condition occurred in the receive shift register. This happens
when additional data arrives while the FIFO is full. In this case the previous data in the receive shift register
is overwritten. Note that under this condition the data byte in the receive shift register is not transferred into
the FIFO, therefore the data in the FIFO is not corrupted by the error.
LSR[2]: Receive Data Parity Error Flag
Logic 0 = No parity error (default).
Logic 1 = Parity error. The receive character in RHR does not have correct parity information and is suspect.
This error is associated with the character available for reading in RHR.
LSR[3]: Receive Data Framing Error Flag
Logic 0 = No framing error (default).
Logic 1 = Framing error. The receive character did not have a valid stop bit(s). This error is associated with
the character available for reading in RHR.
LSR[4]: Receive Break Flag
Logic 0 = No break condition (default).
Logic 1 = The receiver received a break signal (RX was LOW for at least one character frame time). In the
FIFO mode, only one break character is loaded into the FIFO. The break indication remains until the RX
input returns to the idle condition.
LSR[5]: Transmit Holding Register Empty Flag
This bit is the Transmit Holding Register Empty indicator. The THR bit is set to a logic 1 when the last data byte
is transferred from the transmit holding register to the transmit shift register. The bit is reset to logic 0
concurrently with the data loading to the transmit holding register by the host. In the FIFO mode this bit is set
when the transmit FIFO is empty, it is cleared when the transmit FIFO contains at least 1 byte.
LSR[6]: THR and TSR Empty Flag
This bit is set to a logic 1 whenever the transmitter goes idle. It is set to logic 0 whenever either the THR or
TSR contains a data character. In the FIFO mode this bit is set to a logic 1 whenever the transmit FIFO and
transmit shift register are both empty.
LSR[7]: Receive FIFO Data Error Flag
Logic 0 = No FIFO error (default).
Logic 1 = A global indicator for the sum of all error bits in the RX FIFO. At least one parity error, framing error
or break indication is in the FIFO data. This bit clears when there is no more error(s) in any of the bytes in the
RX FIFO.
4.10
Modem Status Register (MSR) - Read Only
This register provides the current state of the modem interface input signals. In the normal mode of operation,
none of the modem inputs (CTS, DSR, RI and CD) will change. However, all of the modem inputs can be
controlled in internal loopback mode.
Lower four bits of this register are used to indicate the changed
information. These bits are set to a logic 1 whenever a signal from the modem changes state.
MSR[0]: Delta CTS Input Flag
Logic 0 = No change on CTS input (default).
Logic 1 = The CTS input has changed state since the last time it was monitored. A modem status interrupt
will be generated if MSR interrupt is enabled (IER bit-3).
相关PDF资料
PDF描述
6374611-1 C/A 2.0MM SM LC-SC 1M1
RBC15DCST-S288 CONN EDGECARD 30POS .100 EXTEND
VI-JTV-EZ-S CONVERTER MOD DC/DC 5.8V 25W
AD8016ARE-EVAL BOARD EVAL FOR AD8016ARE
UPJ0J681MPD1TD CAP ALUM 680UF 6.3V 20% RADIAL
相关代理商/技术参数
参数描述
XR19L200IL32-0B-EB 功能描述:界面开发工具 Supports L200 32 pin QFN, PCI Interface RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V
XR19L200IL32-F 功能描述:UART 接口集成电路 UART RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel
XR19L202 制造商:EXAR 制造商全称:EXAR 功能描述:TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L202IL48 制造商:EXAR 制造商全称:EXAR 功能描述:TWO CHANNEL INTEGRATED UART AND RS-232 TRANSCEIVER
XR19L202IL48-0B-EB 功能描述:界面开发工具 Supports L202 48 pin QFN,PCI Interface RoHS:否 制造商:Bourns 产品:Evaluation Boards 类型:RS-485 工具用于评估:ADM3485E 接口类型:RS-485 工作电源电压:3.3 V