5-23
FOR FURTHER TECHNICAL
DETAILS ON THIS
PRODUCT REQUEST
AIR PREPARATION
MODULAR TYPE – ACCESSORIES
Air
Pr
epar
ation
Castle Hill NSW.............Tel: (02) 680 3222.....Fax: (02) 894 5719
ORDER LINES
Tel: 01-501822 Fax: 01-502710
ORDER LINES
SEE INSIDE FRONT COVER FOR
DETAILS OF YOUR LOCAL SALES OFFICE
MEMBRANE AIR DRYER
SERIES IDG
Outlet air flow range 50, 100, 200, 300 and 500
l/min at
-20C outlet dewpoint
No exter nal power source r equir ed
Envir onmentally friendly non-freon
Lightweight and compact. Easy to handle
No vibration or exhaust heat
Dew point indicator for easy inspection of air dr ying condition
Thr ee atmospheric dew point options -15C (H), -20C (std), and
-40C (L - demanded by semi-conductor industr y)
Optional one touch fitting to exhaust pur ge air
Modular assembly available with integral prefilters (AFM/AFD)
S YMBOL
T ECHNICAL
SPECIFICATIONS
The Membrane Air Dryer uses hollow fibre made of a
high molecular membrane which has the
characteristics of passing water vapour easily, but not
to pass air/gas.
Air/gas
Water vapour
When humid air is supplied to the inside of the hollow
fibre tube and dry air reduced to near atmospheric
pressure is supplied to the outside of the hollow fibre
tube as purge air, water vapour penetrates from the
inside of the membrane to the outside due to the
pressure differential between the water vapour inside
the tube and the purge air outside. With this principle,
the compressed air which passes through the hollow
fibre tube is dehumidified.
NOTE: This product will be released during 1998. Please
contact your SMC Regional Centre for the latest information.
H OW T O
O R D E R
S INGLE
U NIT
IDG
5 …… 50
10 … 100
20 … 200
30 … 300
50 … 500
S IZE /F LOW (L/ MIN )
Nil … -20
H …… -15
L …… -40
D EW P OINT C
01 … 1/8
02 … 1/4
03 … 3/8
P OR T S IZE
Nil … Standar d
P …… W ith one-touch fitting for pur ge air dischar ge
R …… Flow dir ection (Right to Left)
S …… W ith dew point indicator (only with IDG5) - (Other
sizes have indicator as standard)
O PTION
Nil … - (standar d)
B …… W ith bracket
A CCESSORIES
S TOCKED P RODUCTS
FOR A LIST OF STOCKED PRODUCTS,
PLEASE SEE THE CURRENT
SMC PRICE LIST
BM59
for IDG5, 5H
BM61
for IDG10, 10H
BM63
for IDG20, 20H
BM64
for IDG30, 30H, 30L, 50, 50H, 50L
ACCESSORIES
BRACKET SET
IDG-EL5
for IDG5
IDG-EL5H
for IDG5H
IDG-EL10
for IDG10
IDG-EL10H
for IDG10H
IDG-EL20
for IDG20
IDG-EL20H
for IDG20H
IDG-EL30
for IDG30, 30H, 30L
IDG-EL50
for IDG50, 50H, 50L
ACCESSORIES
MEMBRANE MODULE SET
Precautions
Operating conditions
(1) Always use within standard
specifications
(2) Read the Operation manual attached
for correct use
(3) Do NOT use in environments of
corrosive gas, compressed air including
organic solvent, etc.
(4) Do NOT use with breathing air
equipment.