参数资料
型号: YM05S05
厂商: Power-One
文件页数: 7/24页
文件大小: 0K
描述: CONVERT DC/DC POL NON-ISOLATED
标准包装: 600
系列: *
YM05S05 DC-DC Converter
3.0-5.5 VDC Input; 0.7525-3.63 VDC Programmable @ 5 A
Data Sheet
The figures are numbered as Fig. x.y, where x
indicates the different output voltages, and y
associates with specific plots (y = 1 for the vertical
thermal derating, …). For example, Fig. x.1 will refer
to the vertical thermal derating for all the output
voltages in general.
The following pages contain specific plots or
waveforms associated with the converter. Additional
comments for specific data are provided below.
Test Conditions
All data presented were taken with the converter
soldered to a test board, specifically a 0.060” thick
printed wiring board (PWB) with four layers. The top
and bottom layers were not metalized. The two inner
layers, comprising two-ounce copper, were used to
provide traces for connectivity to the converter.
The lack of metalization on the outer layers as well
as the limited thermal connection ensured that heat
transfer from the converter to the PWB was
minimized. This provides a worst-case but consistent
scenario for thermal derating purposes.
All measurements requiring airflow were made in the
vertical and horizontal wind tunnel facilities using
Infrared (IR) thermography and thermocouples for
thermometry.
Ensuring components on the converter do not
exceed their ratings is important to maintaining high
reliability. If one anticipates operating the converter
at or close to the maximum loads specified in the
derating curves, it is prudent to check actual
operating temperatures in the application.
Thermographic imaging is preferable; if this
capability is not available, then thermocouples may
be used. . It is recommended the use of AWG #40
gauge thermocouples to ensure measurement
accuracy. Careful routing of the thermocouple leads
will further minimize measurement error. Refer to
Fig. C for optimum measuring thermocouple location.
temperature of 120 °C. Ambient temperature was
varied between 25 °C and 85 °C, with airflow rates
from 30 to 500 LFM (0.15 m/s to 2.5 m/s), and
vertical and horizontal converter mounting.
For each set of conditions, the maximum load
current is defined as the lowest of:
(i) The output current at which any MOSFET
temperature does not exceed a maximum specified
temperature of 120 °C as indicated by the
thermographic image, or
(ii) The maximum current rating of the converter
(5 A).
During normal operation, derating curves with
maximum FET temperature less than or equal to
120 °C should not be exceeded. Temperature on the
PCB at the thermocouple location shown in Fig. C
should not exceed 120 °C in order to operate inside
the derating curves.
Efficiency
Fig. x.3 show the efficiency vs. load current plot for
ambient temperature of 25 oC, airflow rate of
200 LFM (1m/s) and input voltages of 4.5 V, 5.0 V
and 5.5 V.
Fig. x.4 show the efficiency vs. load current plot for
ambient temperature of 25 oC, airflow rate of
200 LFM (1m/s) and input voltages of 3.0 V, 3.3 V,
and 3.6 V for output voltages ? 2.5 V.
Power Dissipation
Fig. 3.3V.4 shows the power dissipation vs. load
current plot for Ta = 25 oC, airflow rate of 200 LFM
(1m/s) with vertical mounting and input voltages of
4.5 V, 5.0 V and 5.5 V for 3.3 V output.
Ripple and Noise
The output voltage ripple waveform is measured at
full rated load current. Note that all output voltage
waveforms are measured across a 1 ? F ceramic
capacitor.
The output voltage ripple and input reflected ripple
current waveforms are obtained using the test setup
shown in Fig. D.
i S
1 ? H
Vin
Vout
Fig. C : Location of the thermocouple for thermal testing.
Thermal Derating
source
inductance
V source
C IN
4 x 47 ? F
ceramic
capacitor
GND
Y-Series
DC/DC
Converter
GND
1 ? F
ceramic
capacitor
C O
47 ? F
ceramic
capacitor
Vout
Load current vs. ambient temperature and airflow
rates are given in Figs. x.1 to x.2 for maximum
Fig. D : Test Setup for measuring input reflected ripple
currents, i s and output voltage ripple.
ZD-01978 Rev. 3.2, 18-Jun-10
www.power-one.com
Page 7 of 24
相关PDF资料
PDF描述
YM12S05 CONVERT DC/DC POL NON-ISOLATED
YNC12S20-0 CONVERT DC/DC PROGRAM SMD
YNL05S10012-0 CONVERT DC/DC 1.2V OUT 12W SMD
YNL12S10018-DG CONVERT DC/DC 1.8V OUT 18W SMD
YNM05S05-G CONVERT DC/DC 18.15W SMD
相关代理商/技术参数
参数描述
YM05S05-G 功能描述:DC/DC转换器 0.7525-3.63Vout 5A 3-5.5VIn RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
YM05S05-G-Q 功能描述:DC/DC CONVERTER 5V 18W 制造商:bel power solutions 系列:Y 包装:剪切带(CT) 零件状态:停产 类型:非隔离 PoL 模块 输出数:1 电压 - 输入(最小值):3V 电压 - 输入(最大值):5.5V 电压 - 输出 1:0.7525 ~ 3.63 V 电压 - 输出 2:- 电压 - 输出 3:- 电流 - 输出(最大值):5A 功率(W) - 制造系列:18W 电压 - 隔离:- 应用:ITE(商业) 特性:远程开/关,OCP,OTP,UVLO 安装类型:表面贴装 封装/外壳:5-SMD 模块 大小/尺寸:0.80" 长 x 0.45" 宽 x 0.26" 高(20.3mm x 11.4mm x 6.6mm) 工作温度:-40°C ~ 85°C 效率:94% 功率(W) - 最大值:18W 标准包装:1
YM05S06 制造商:Power-One 功能描述:
YM05S06-G 制造商:Power-One 功能描述:
YM06132C05NQ 制造商:CK-COMPONENTS 制造商全称:C&K Components 功能描述:4 Tumbler Miniature Switchlocks