YMU759B
-4-
Terminal functions
No.
Name
I/O
Function
1
CLKI
Ish
Clock input (2MHz
~20MHz)
2
EXT1
O
External device control terminal 1 (*1)
3
/IRQ
O
Interruption output
4
/RST
Ish
Hardware reset input
5
IFSEL
I
CPU I/F selection
L: Serial I/F, H: Parallel I/F
6
PLLC
A
Connection of capacitor for built in PLL
Connect the 3.3k
resistance and the 1000pF capacitor between this terminal
and VSS (*) in series.
(*)Directly connect VSS used here and VSS of 8th pin.
7
VDD
-
Digital power supply (Typically +3.0V)
Connect 0.1
F and 4.7 F capacitors between this terminal and VSS
8
VSS
-
Ground
9
VREF
A
Analog reference voltage.
Connect 0.1
F capacitor between this terminal and VSS
10
HPOUT-L / MONO
A
Headphone L channel output: can be switched to mono through register setting
11
HPOUT-R
A
Headphone R channel output
12
EQ1
A
Equalizer terminal 1
13
EQ2
A
Equalizer terminal 2
14
EQ3
A
Equalizer terminal 3
15
SPVDD
-
Analog power supply (Typically +3.6 V)
Connect 0.1
F and 4.7 F capacitors between this terminal and SPVSS
16
SPVSS
-
Analog ground for speaker amplifier
17
SPOUT1
A
Speaker terminal 1
18
SPOUT2
A
Speaker terminal 2
19
EXT2
O
External device control terminal 2 (*1)
20
D7
I/O
Parallel I/F data bus 7 (*1)
21
D6
I/O
Parallel I/F data bus 6 (*1)
22
D5
I/O
Parallel I/F data bus 5 (*1)
23
D4
I/O
Parallel I/F data bus 4 (To be open when IFSEL=L)
24
D3
I/O
Parallel I/F data bus 3 (To be open when IFSEL=L)
25
D2
I/O
Parallel I/F data bus 2 (To be open when IFSEL=L)
26
D1
I/O
Parallel I/F data bus 1 (To be open when IFSEL=L)
27
D0
I/O
Parallel I/F data bus 0 (To be open when IFSEL=L)
28
/WR
Ish
Parallel I/F write pulse (To be open when IFSEL=L)
29
SDIN (/CS)
Ish
IFSEL= L Serial I/F data input
IFSEL= H Parallel I/F chip select input
30
SYNC (A0)
Ish
IFSEL= L Serial I/F data decision signal
IFSEL= H Parallel I/F address signal
31
SCLK (/RD)
Ish
IFSEL= L Serial I/F bit clock input
IFSEL= H Parallel I/F read pulse
32
SDOUT
OD
Serial I/F data output (Pull up resistance is necessary for the outside)
Comment: Ish= Schmitt input, OD= open drain terminal, A= Analog terminal