YPB09S30 30A DC-DC Converter Data Sheet
4.5V to 13.5V Input 0.8V to 1.8V Output
Preliminary
ZD-01734 Rev 1.1, 24-Jun-10
www.power-one.com
Page 2 of 6
1.
Ordering Information
Y
PB
09
S
60
–
0
z
Product
Family
Series
Input
Voltage
PCB
Mounting
Output
Current
Dash
Special
Features
RoHS compliance
POL
Converter
Power
Block
4.5V to
13.5V
SMT
30A
Integrated
Heatsink
No suffix
- RoHS compliant with Pb
solder exemption
1
G
- RoHS compliant for all six substances
______________________________________
1
The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium
(Cr6+), Mercury (Hg), Polybrominated biphenyls, Polybrominated diphenylethers, and Lead (Pb) used anywhere except in solder.
Example: YPB09S30-0G: YPB09S30 Power Block with integrated heatsink and lead-free solder.
2.
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long-
term reliability, and cause permanent damage to the converter.
Parameter
Conditions/Description
Min
Max
Units
Input Voltage
Continuous
-0.3
16
VDC
Ambient Temperature Range
Operating, With Proper Current Derating
0
85
C
Storage Temperature (Ts)
-55
125
C
3.
Environmental and Mechanical Specifications
Parameter
Conditions/Description
Min
Nom
Max
Units
Operating Ambient
Temperature Range
Continuous
1
72-Hrs Survival
23
0
55
70
C
Available airflow
Along either long or short side
200
LFM
Operating and Storage
Humidity
RH (non-condensing)
10
90
%
Operating Altitude
4
-500
10,000
Feet
Sinusoidal Vibration
GR-63-CORE, Sect. 5.4.2
1
g
Shock
Half Sinewave, 3-axis
50
g
Weight
0.44
oz
MTBF
Calculated Per Telcordia Technologies SR-332,
Full Load, TAMB=40°C, Ground Benign
3
MHrs
Lead Plating
YPB09S30-0 and YPB09S30-0G
100% Matte Tin
1 Component temperatures will not exceed Power-One derating guidelines with up to 3 converters operating side
by side spaced 0.1” apart
2 For single converter, component temperatures can exceed Power-One derating guidelines, but will not exceed
component absolute maximum temperature ratings
3 With up to 3 converters operating side by side spaced 0.1” apart, component temperatures will not activate OTP,
and will not compromise long-term reliability
4 Derate maximum operating temperature by 1°C per 1,000 Feet of altitude above sea level