参数资料
型号: 10961
厂商: 3M
文件页数: 4/6页
文件大小: 0K
描述: MDR CUTTING UNIT
标准包装: 1
系列: MDR
附件类型: 切割单位
其它名称: 90169008567
JE150172870
Figure 8. Wires in “U” slot cover
Figure 10. Cut wires
8
10
Figure 9. 2nd cover on top of wires
Figure 11. Connector body
9
11
E. Repeat for the next conductor, except position it to
the rear and right. Place the next wire in the left slot
(adjacent to the first one), followed by another wire
in the right slot, etc., until all conductors are
in position. Proceed to Step 5.
0.025” Flat Ribbon Cable
A. To use the fixture unit, first remove the cable clamp
stop (B of Fig. 6) from the fixture unit. This is done
so that the flat cable may be inserted into the
fixture unit without obstruction.
B. Slide the prepared cable end into the fixture slot so
the first conductor is towards the back, facing
the left side.
C. Lay the conductors into the grooved wire holding slot
accordingly until all conductors are positioned.
Proceed to Step 5.
7.
8.
9.
10.
11.
12.
Push shuttle block with fixture unit and cable
subassembly away from the operator, back under
the cutting unit, until it contacts the shuttle stop.
Pull the press handle down and release, cutting
the wires (Fig. 10).
Push platen back into place using the side bar.
Pull the shuttle out. Placing one finger near the center
of the covers to prevent movement or wire dislocation,
remove the cut wires from the fixture unit.
Push the release buttons on the front of the fixture unit to
allow placement of the connector body over the covers
(Fig. 11). Make sure the alignment tab on the inside end
of the connector body is aligned with the notch on the
second cover, nearest the operator. Push the connector
body down over the covers until a slight “click” is heard.
Push shuttle block, with fixture unit and cable
5.
Pick up second cover and rub the paper liner to ensure
subassembly, away from the operator until it stops.
6.
transfer of adhesive to the cover. Remove the paper liner
from the back of the second cover and place the cover
(adhesive side down) over the wires and first cover,
aligning it with the first cover’s guide pins. Keep the
notched end toward the operator. Press it down on
the first cover’s guide posts (Fig. 9).
Slide the platen assembly forward using the side bar
13.
14.
15.
Pull press handle completely down, pressing connector
body onto the covers and subassembly.
Lift handle and pull shuttle block and assembly
toward the operator.
Completed assembly may now be removed
from the fixture unit.
on the operator’s left side to reveal the cutting unit.
4
相关PDF资料
PDF描述
OPTL-3-MSL TRIPLE MICRO SUB-LENS
OPI-O1011 LENS BASE MOD SPOT NICHIA 11DEG
OPIO-1-011 SPOT BASE MODULE 11 DEG
OPX-P1SPOT CREE XP ADBACK OPTIC SPOT
OPX-P1SDIF CREE XP ADBACK OPT FRSTD SPT
相关代理商/技术参数
参数描述
1096100000 制造商:Weidmuller 功能描述:SL 7.62HP/09/90LF 3.2SN OR BX
109611 制造商:未知厂家 制造商全称:未知厂家 功能描述:SUPERKLEMMEN NR 1 5ST Inhalt pro Packung: 5 Stk.
1096110000 制造商:Weidmuller 功能描述:SL 7.62HP/10/90LF 3.2SN OR BX
1096120000 制造商:Weidmuller 功能描述:SL 7.62HP/11/90LF 3.2SN OR BX
10-961-2-05 制造商:Concord Electronics Inc 功能描述: