Product specification
74LV4799
Timer for NiCd and NiMH chargers
1998 Apr 20
5
Self-discharge mode.
If DIS is HIGH and PWRS is inactive (LOW or open), the battery is
being neither charged nor discharged. The circuit is in the
self-discharge mode. This mode represents the battery leakage
(self-discharge). The counter counts down. The clock frequency is
determined by the external capacitor and resistor at the RS output.
When the counter reaches the zero state, it stops.
LED mode select.
The LED output drives a battery status LED which indicates the
charge/full status of the battery. For optimum flexibility, two modes of
operation are built-in.
Mode 1: If SEL is LOW, the LED output is active LOW in the
charge mode, and the LED blinks with a frequency of
about 1 Hz during trickle charge.
Mode 2: If SEL is HIGH or open, the LED output blinks with a
frequency of about 0.25 Hz in the charge mode, and is
active LOW during trickle charge. In the discharge or
self-discharge mode, the LED output is open except
when PWRS is active (HIGH or pulsed). Then, the
battery is charging and discharging simultaneously.
Although the discharge mode is dominant, the LED
output is active when PWRS is also active.
NOTE: The blink frequency depends on the oscillator frequency.
(See application information)
Low indication.
As part of the user interface, the MOLLI output shows when the
battery needs to be charged. MOLLI stands for More Or Less Low
Indication (active LOW). The function is as follows: In the discharge
mode, (DIS is active LOW), the counter counts down and, when it
reaches the zero state, it stops. If DIS is switched HIGH, the MOLLI
output gives an output signal of four periods of about one second,
with a 50% duty cycle. This can be used to activate a buzzer. The
MOLLI output signal of four periods will be interrupted as soon as
PWRS is activated.
Alarm indication.
If an almost completely discharged battery is connected to the
charger, it may not be noticed by the user if the load switch is still
on. To prevent damaging the battery, an alarm signal on the LED
output will alert the user to switch off the load. The alarm signal is
easily recognized, because the LED output will blink at a higher
frequency than normal (about 5 Hz instead of 1 Hz). This alarm
indication is only active if the SEL input is HIGH or open. If the SEL
input is LOW, no alarm indication is present, because in many
applications simultaneous charging and discharging is quite
acceptable. (See charge/discharge mode)
Scan test mode.
If the SCAN input (pin 14) is made active HIGH, the circuit is in the
test mode. The tester clock is connected to the IOSC pin (pin 13). In
the scan mode, the on–chip oscillator is bypassed to allow rapid
testing of the divider/counter. The scan test patterns are available on
request. The scan test data is entered serially through the SCI input
(pin 15). The scan out data is present on the MOLLI/SCO output
(pin 6), which then acts as a scan output.
Remaining energy indication.
The scan test facility can be used as a remaining energy indication
because the value of the counter can be read out at the scan output
(MOLLI/SCO). This is done by briefly interrupting the normal mode
of operation, putting the circuit in the scan mode, and reading out
the counter value. The circuit then reverts to the normal mode. This
only works correctly with the MOLLI/SCO output and SCI input
linked (round coupled loop) and with exactly 49 clock pulses applied
to the IOSC input.
The serial scan-out data is available on the MOLLI/SCO output. The
value of the counter can be decoded by reading the correct bits.
Details are given later in the section “Application information”.
Output drivers EN and EN.
In one-cell battery (low-voltage) applications, the drive from the
ENABLE output (EN) is insufficient to provide the base current directly
for the external bipolar PNP regulator transistor. The inverse signal has
therefore been made available at the ENABLE output (EN) to drive an
extra bipolar NPN transistor that can provide the base current for the
bipolar PNP regulator transistor as shown in Figure 2.
FUNCTION TABLE 1
OPERATING
INPUTS
OUTPUTS
DIVIDER/COUNTER
OPERATING
MODES
PWRS
VIN
DIS
EN
RC
RD
RS
MODE
VALUE
Charge
H or
H
L
Z
Count up 22 sections
< max
Trickle charge
H or
H
Z
Stop
max
Charge/discharge
H or
H
L
H
L
Z
Count down 18 sections
≥ min
Discharge
L or open
X
L
Z
Count down 18 sections
≥ min
Self-discharge
L or open
X
H
L
Z
Count down 27 sections
≥ min
相关PDF资料
PDF描述
74V2G66CTR DUAL 1-CHANNEL, SGL POLE SGL THROW SWITCH, PDSO8
74V2T66CTR DUAL 1-CHANNEL, SGL POLE SGL THROW SWITCH, PDSO8
7705201FC 8-CHANNEL, SGL ENDED MULTIPLEXER, CDFP16
7705201FA 8-CHANNEL, SGL ENDED MULTIPLEXER, CDFP16
7705201EA 8-CHANNEL, SGL ENDED MULTIPLEXER, CDIP16
相关代理商/技术参数
参数描述
74LV4799PW-T 功能描述:计时器和支持产品 3.3V TIMER NICD AND NIMH CHARGER RoHS:否 制造商:Micrel 类型:Standard 封装 / 箱体:SOT-23 内部定时器数量:1 电源电压-最大:18 V 电源电压-最小:2.7 V 最大功率耗散: 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装:Reel
74LV4799SD,118 功能描述:IC OSC TIMER CTRL 100KHZ 16SOIC RoHS:是 类别:集成电路 (IC) >> 时钟/计时 - 可编程计时器和振荡器 系列:74LV 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:45 系列:- 类型:温度 - 补偿晶体振荡器(TCXO) 计数:- 频率:25MHz 电源电压:3.135 V ~ 3.465 V 电流 - 电源:1.5mA 工作温度:-40°C ~ 85°C 封装/外壳:16-SOIC(0.295",7.50mm 宽) 包装:管件 供应商设备封装:16-SOIC W 安装类型:表面贴装
74LV540A 制造商:TI 制造商全称:Texas Instruments 功能描述:OCTAL BUFFERS/DRIVERS WITH 3-STATE OUTPUTS
74LV540APWJ 功能描述:74LV540APW/SOT360/TSSOP20 制造商:nexperia usa inc. 系列:* 零件状态:在售 标准包装:2,500
74LV541 制造商:PHILIPS 制造商全称:NXP Semiconductors 功能描述:Octal buffer/line driver 3-State