参数资料
型号: AD7691BRMZ-RL7
厂商: Analog Devices Inc
文件页数: 13/28页
文件大小: 0K
描述: IC ADC 18BIT SAR 250KSPS 10-MSOP
标准包装: 1,000
系列: PulSAR®
位数: 18
采样率(每秒): 250k
数据接口: DSP,MICROWIRE?,QSPI?,串行,SPI?
转换器数目: 1
功率耗散(最大): 12.5mW
电压电源: 模拟和数字
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 10-TFSOP,10-MSOP(0.118",3.00mm 宽)
供应商设备封装: 10-MSOP
包装: 带卷 (TR)
输入数目和类型: 1 个差分,双极
配用: EVAL-AD7691CBZ-ND - BOARD EVALUATION FOR AD7691CBZ
AD7691
Data Sheet
Rev. C | Page 20 of 28
CS MODE, 4-WIRE WITHOUT BUSY INDICATOR
This mode is usually used when multiple AD7691s are
connected to an SPI-compatible digital host.
A connection diagram example using two AD7691s is shown in
Figure 39, and the corresponding timing is given in Figure 40.
With SDI high, a rising edge on CNV initiates a conversion,
selects the CS mode, and forces SDO to high impedance. In this
mode, CNV must be held high during the conversion phase and
the subsequent data readback. (If SDI and CNV are low, SDO is
driven low.) Prior to the minimum conversion time, SDI can be
used to select other SPI devices, such as analog multiplexers,
but SDI must be returned high before the minimum conversion
time elapses and then held high for the maximum possible
conversion time to avoid the generation of the busy signal
indicator. When the conversion is complete, the AD7691 enters
the acquisition phase and powers down. Each ADC result can
be read by bringing its SDI input low, which consequently
outputs the MSB onto SDO. The remaining data bits are clocked
by subsequent SCK falling edges. The data is valid on both SCK
edges. Although the rising edge can be used to capture the data,
a digital host using the SCK falling edge allows a faster reading
rate, provided it has an acceptable hold time. After the 18th SCK
falling edge, or when SDI goes high, whichever occurs first, SDO
returns to high impedance and another AD7691 can be read.
DATA IN
CLK
CS1
CONVERT
CS2
DIGITAL HOST
CNV
SCK
SDO
SDI
CNV
SCK
SDO
SDI
AD7691
06
14
6-
0
1
5
Figure 39. 4-Wire CS Mode Without Busy Indicator Connection Diagram
SDO
D17
D16
D15
D1
D0
tDIS
SCK
12
3
34
35
36
tHSDO
tDSDO
tEN
CONVERSION
ACQUISITION
tCONV
tCYC
tACQ
ACQUISITION
SDI (CS1)
CNV
tSSDICNV
tHSDICNV
D1
16
17
tSCK
tSCKL
tSCKH
D0
D17
D16
19
20
18
SDI (CS2)
06
14
6-
0
16
Figure 40. 4-Wire CS Mode Without Busy Indicator Serial Interface Timing
相关PDF资料
PDF描述
MS3106F24-22S CONN PLUG 4POS STRAIGHT W/SCKT
VE-B7J-MY CONVERTER MOD DC/DC 36V 50W
ADM3307EARUZ-REEL7 IC TXRX RS-232 5:3 2.7V 28TSSOP
CXS3106A282P CONN PLUG 14POS STRGHT PIN
LTC2850CDD#TRPBF IC TXRX RS485 20MBPS 8-DFN
相关代理商/技术参数
参数描述
AD7693 制造商:AD 制造商全称:Analog Devices 功能描述:16-Bit Lower Power
AD76931 制造商:AD 制造商全称:Analog Devices 功能描述:18-Bit, 2 MSPS PulSAR 15 mW ADC in LFCSP (QFN)
AD7693BCPZ 制造商:Analog Devices 功能描述:ADC SGL SAR 500KSPS 16BIT SERL 10LFCSP - Rail/Tube
AD7693BCPZ-R2 制造商:Rochester Electronics LLC 功能描述: 制造商:Analog Devices 功能描述:
AD7693BCPZRL 功能描述:IC ADC 16BIT 500KSPS 10LFCSP RoHS:是 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:PulSAR® 标准包装:1 系列:- 位数:14 采样率(每秒):83k 数据接口:串行,并联 转换器数目:1 功率耗散(最大):95mW 电压电源:双 ± 工作温度:0°C ~ 70°C 安装类型:通孔 封装/外壳:28-DIP(0.600",15.24mm) 供应商设备封装:28-PDIP 包装:管件 输入数目和类型:1 个单端,双极