AD9100
REV. B
–3–
EXPLANATION OF TEST LEVELS
Test Level
I
– 100% production tested.
II
– 100% production tested at +25
°
C, and sample tested at
specified temperatures.
III – Periodically sample tested.
IV – Parameter is guaranteed by design and characterization
testing.
V
– Parameter is a typical value only.
VI – All devices are 100% production tested at +25
°
C. 100%
production tested at temperature extremes for extended
temperature devices; sample tested at temperature
extremes for commercial/industrial devices.
ORDERING GUIDE
Temperature
Range
0
°
C to +70
°
C
–40
°
C to +85
°
C
–55
°
C to +125
°
C
Package
Description
Package
Option
Model*
AD9100JD
AD9100AD
AD9100SD
Ceramic DIP
Ceramic DIP
Ceramic DIP
D-20
D-20
D-20
*Consult factory about availability of parts screened to MIL-STD-883.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD9100 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
EVALUATION BOARD ORDERING INFORMATION
Part Number
Description
AD9100/PWB
Printed Wiring Board (Only) of Evaluation
Circuit
Evaluation Board for AD9100T/H, Assembled
and Tested [Order AD9100T/H (DIP)
Separately]
AD9100/PCB
CLOCK
+2V
0V
–2V
AINPUT
+2V
0V
–2V
"1"
"0"
CLOCK (PIN #19)
CLOCK
TO
DELAY
TIME
ADELAY
(0.8ns)
"TRACK"
LVOLTAGE
"HOLD"
"HOLD"
TRACK TO
HOLD
SETTLING
(7ns)
ANALOG OUTPUT
HOBSERVED AT
AOBSERVED AT
ACQU(16ns)
Figure 1. Timing Diagram (1 ns/div)
ABSOLUTE MAXIMUM RATINGS
1
Supply Voltages (
±
V
S
) . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
6 V
Continuous Output Current . . . . . . . . . . . . . . . . . . . . . 70 mA
Analog Input Voltage
2
. . . . . . . . . . . . . . . . . . . . . . . . . . .
±
5 V
Operating Temperature Range (Case)
AD9100JD . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
°
C to +70
°
C
AD9100AD . . . . . . . . . . . . . . . . . . . . . . . . .–25
°
C to +85
°
C
AD9100SD . . . . . . . . . . . . . . . . . . . . . . . .–55
°
C to +125
°
C
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . +175
°
C
Storage Temperature . . . . . . . . . . . . . . . . . . .–65
°
C to +150
°
C
Lead Soldering Temperature (10 sec) . . . . . . . . . . . . . +300
°
C
NOTES
1
Absolute maximum ratings are limiting values to be applied individually, and
beyond which the serviceability of the circuit may be impaired. Functional
operability is not necessarily implied. Exposure to absolute maximum rating
conditions for an extended period of time may affect device reliability.
2
Analog input voltage should not exceed
±
V
S
.