ADATE305
Rev. 0 | Page 15 of 56
Parameter
Min
Typ
Max
Unit
Test
Level
Conditions/Comments
Output Short-Circuit Current
25
+25
mA
P
PMU enabled, FVMV, PE disabled; source: PMU force +6.0 V,
short MEASOUT01 to 1.5 V; sink: PMU force 1.5 V, short
MEASOUT01 to +6.0 V
VOLTAGE CLAMPS
Low Clamp Range (VCL)
1.5
+4.0
V
D
High Clamp Range (VCH)
0.0
6.0
V
D
Positive Clamp Voltage Droop
300
+10
+300
mV
P
PMU enabled, FIMI, Range A, PE disabled, PMU clamps
enabled, VCH = 5 V,VCL = 1 V, PMU force 2 mA and 32 mA
into open; V seen at DUTx pin
Negative Clamp Voltage Droop
300
10
+300
mV
P
PMU enabled, FIMI, Range A, PE disabled, PMU clamps
enabled, VCH = 5 V,VCL = 1 V, PMU force 2 mA and 32 mA
into open; V seen at DUTx pin
Uncalibrated Accuracy
250
±100
+250
mV
P
PMU enabled, FIMI, Range B, PE disabled, PMU clamps enabled,
PMU force ±1 mA into open; VCH errors at calibration points 0 V
and 5 V; VCL errors at the calibration points 0 V and 4 V
INL
70
±5
+70
mV
P
PMU enabled, FIMI, Range B, PE disabled, PMU clamps enabled,
PMU force ±1 mA into open; after two-point gain/offset
calibration; measured over PMU clamp range
DUTGND Voltage Accuracy
±1
mV
CT
Over ±0.1 V range; measured at end points of PMU clamp
functional range
SETTLING/SWITCHING TIMES
SCAP = 330 pF, FFCAP = 220 pF
Voltage Force Settling Time to
0.1% of Final Value:
PMU enabled, FV, PE disabled, program PMUDAC steps of
500 mV and 5.0 V; simulation of worst case, 2000 pF load,
PMUDAC step of 5.0 V
Range A, 200 pF and
2000 pF Load
15
μs
S
Range B, 200 pF and
2000 pF Load
20
μs
S
Range C, 200 pF and
2000 pF Load
124
μs
S
Range D, 200 pF and
2000 pF Load
1015
μs
S
Range E, 200 pF and
2000 pF Load
3455
μs
S
Voltage Force Settling Time to
1.0% of Final Value:
PMU enabled, FV, PE disabled, start with PMUDAC
programmed to 0.0 V, program PMUDAC to 500 mV
Range A, 200 pF and
2000 pF Load
14
μs
CB
Range B, 200 pF and
2000 pF Load
14
μs
CB
Range C, 200 pF and
2000 pF Load
14
μs
CB
Range D, 200 pF Load
45
μs
CB
Range D, 2000 pF Load
45
μs
CB
Range E, 200 pF Load
45
μs
CB
Range E, 2000 pF Load
225
μs
CB
Voltage Force Settling Time to
1.0% of Final Value:
PMU enabled, FV, PE disabled, start with PMUDAC
programmed to 0.0 V, program PMUDAC to 5.0 V
Range A, 200 pF and
2000 pF Load
4.0
μs
CB
Range B, 200 pF Load
4.2
μs
CB
Range B, 2000 pF Load
4.2
μs
CB
Range C, 200 pF Load
5.8
μs
CB
Range C, 2000 pF Load
19
μs
CB
Range D, 200 pF Load
50
μs
CB
Range D, 2000 pF Load
210
μs
CB
Range E, 200 pF Load
360
μs
CB
Range E, 2000 pF Load
610
μs
CB