参数资料
型号: CS5460A-BSZR
厂商: Cirrus Logic Inc
文件页数: 22/54页
文件大小: 0K
描述: IC ENERGY METERING 1PHASE 24SSOP
标准包装: 1,000
输入阻抗: 30 千欧
测量误差: 0.1%
电压 - 高输入/输出: 0.8V
电压 - 低输入/输出: 0.2V
电流 - 电源: 2.9mA
电源电压: 4.75 V ~ 5.25 V
测量仪表类型: 单相
工作温度: -40°C ~ 85°C
安装类型: 表面贴装
封装/外壳: 24-SSOP(0.209",5.30mm 宽)
供应商设备封装: 24-SSOP
包装: 带卷 (TR)
配用: CDB5460AU-ND - EVALUATION BOARD FOR CS5460A
CS5460A
PR = 500 ------------------ ? -------------- ? ------------------ ? ------------------ ? ------------------
kW ? hr 3600s 1000W
Ign or Vgn = ------------- ? 1.00441 = 0x404830
EXAMPLE #2: The required number of pulses per
unit energy present at EOUT is specified to be
500 pulses/kW-hr; given that the maximum
line-voltage is 250 V (RMS) and the maximum
line-current is 20 A (RMS). In such a situation, the
nominal line voltage and current do not determine
the appropriate pulse-rate setting. Instead, the
maximum line levels must be considered. As be-
fore, the given maximum line-voltage and line-cur-
rent levels are used to determine K V and K I :
K V = 150 mV / 250 V = 0.0006
K I = 150 mV / 20 A = 0.0075 ?
Again the sensor gains are calculated such that the
maximum line-voltage and line-current levels will
measure as 0.6 in the RMS Voltage Register and
RMS Current Register.
The required Pulse-Rate Register setting is now
determined by using the following equation:
pulses 1hr 1kW 250mV 250mV
K V K I
Therefore PR = ~1.929 Hz.
Note that the Pulse-Rate Register cannot be set to
a frequency of exactly 1.929 Hz. The closest set-
ting that the Pulse-Rate Register can obtain is
0x00003E = 1.9375 Hz. To improve the accuracy,
either gain register can be programmed to correct
for the round-off error in PR. This value would be
calculated as
PR
1.929
In the last example, suppose a value for MCLK/K
of 3.05856 MHz. When MCLK/K is not equal to
4.096 MHz, the result for ‘PR’ that is calculated for
the Pulse-Rate Register must be scaled by a cor-
rection factor of: 4.096 MHz / (MCLK/K). In this
case the result is scaled by 4.096/3.05856 to get a
final PR result of ~2.583 Hz.
3.2 Pulse Output for Normal Format,
Stepper Motor Format and Mechanical
Counter Format
The duration and shape of the pulse outputs at the
EOUT and EDIR pins can be set for three different
output formats. The default setting is for Normal
output pulse format. When the pulse is set to either
22
of the other two formats, the time duration and/or
the relative timing of the EOUT and EDIR pulses is
increased/varied such that the pulses can drive ei-
ther an electro-mechanical counter or a stepper
motor. The EOUT and EDIR output pins are capa-
ble of driving certain low-voltage/low-power coun-
ters/stepper motors directly. This depends on the
drive current and voltage level requirements of the
counter/motor. The ability to set the pulse output
format to one of the three available formats is con-
trolled by setting certain bits in the Control Regis-
ter.
3.2.1 Normal Format
Referring to the description of the Control Register
in Section 5., Register Descriptions , if both the
MECH and STEP bits are set to ‘0’, the pulse out-
put format at the EOUT and EDIR pins is illustrated
in Figure 10. These are active-low pulses with very
short duration. The pulse duration is an integer
multiple of MCLK cycles, approximately equal to
1/16 of the period of the contents of the Pulse-Rate
Register. However for Pulse-Rate Register set-
tings less than the sampling rate (which is
[MCLK/8]/1024), the pulse duration will remain at a
constant duration, which is equal to the duration of
the pulses when the Pulse-Rate Register is set to
[MCLK/K]/1024. The maximum pulse frequency
from the EOUT pin is therefore [MCLK/K]/16.
When energy is positive, EDIR is always high.
When energy is negative, EDIR has the same out-
put as EOUT. When MCLK/K is not equal to
4.096 MHz, the true pulse-rate can be found by
first calculating what the pulse-rate would be if a
4.096 MHz crystal is used (with K = 1) and then
scaling the result by a factor of
(MCLK/K) / 4.096 MHz.
When set to run in Normal pulse output format, the
pulses may be sent out in “bursts” depending on
both the value of the Pulse-Rate Register as well
as the amount of billable energy that was regis-
tered by the CS5460A over the most recent A/D
sampling period, which is (in Hz): 1 / [(MCLK/K) /
1024]. A running total of the energy accumulation
is maintained in an internal register (not accessible
to the user) inside the CS5460A. If the amount of
energy that has accumulated in this register over
the most recent A/D sampling period is equal to or
greater than the amount of energy that is repre-
DS487F5
相关PDF资料
PDF描述
EEM08DCMI-S288 CONN EDGECARD 16POS .156 EXTEND
LT3694EFE#TRPBF IC REG TRPL BUCK/LINEAR 20TSSOP
LT3500IMSE#TRPBF IC REG DL BUCK/LINEAR 16-MSOP
GEM06DCMI-S288 CONN EDGECARD 12POS .156 EXTEND
F951A336MQAAQ2 CAP TANT 33UF 10V 20% 1206
相关代理商/技术参数
参数描述
CS5460-BS 制造商:Rochester Electronics LLC 功能描述:- Bulk 制造商:Cirrus Logic 功能描述:
CS5460C-ISZ 功能描述:电流和电力监控器、调节器 Sngl-Phs Bi-Drctnl Power/Energy RoHS:否 制造商:STMicroelectronics 产品:Current Regulators 电源电压-最大:48 V 电源电压-最小:5.5 V 工作温度范围:- 40 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:HPSO-8 封装:Reel
CS5460C-ISZR 功能描述:电流和电力监控器、调节器 IC Sngl-Phs BiDirect PWR/Energy RoHS:否 制造商:STMicroelectronics 产品:Current Regulators 电源电压-最大:48 V 电源电压-最小:5.5 V 工作温度范围:- 40 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:HPSO-8 封装:Reel
CS5460F-ISZ 功能描述:电流和电力监控器、调节器 Sngl-Phs Bi-Drctnl Power/Energy RoHS:否 制造商:STMicroelectronics 产品:Current Regulators 电源电压-最大:48 V 电源电压-最小:5.5 V 工作温度范围:- 40 C to + 150 C 安装风格:SMD/SMT 封装 / 箱体:HPSO-8 封装:Reel