参数资料
型号: DS1921H-F5#
厂商: Maxim Integrated
文件页数: 12/45页
文件大小: 0K
描述: IBUTTON THERMOCHRON F5
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
RoHS指令信息: IButton RoHS Compliance Plan
标准包装: 8
系列: iButton®
存储容量: 512B
存储器类型: NVSRAM(非易失 SRAM)
产品目录页面: 1431 (CN2011-ZH PDF)
Mission Samples Counter Register Map
DS1921H/Z
ADDR
021Ah
021Bh
021Ch
b7
b6
b5
b4 b3
Low Byte
Center Byte
High Byte
b2
b1
b0
DEVICE SAMPLES COUNTER
The Device Samples Counter indicates how many temperature measurements have taken place since the
device was assembled at the factory. The value is stored as an unsigned 24-bit integer number. The
maximum number that can be represented in this format is 16777215, which is higher than the expected
lifetime of the DS1921H/Z devices. This counter cannot be reset under software control.
Device Samples Counter Register Map
ADDR
021Dh
021Eh
021Fh
b7
b6
b5
b4 b3
Low Byte
Center Byte
High Byte
b2
b1
b0
TEMPERATURE LOGGING AND HISTOGRAM
Once setup for a mission, the DS1921H/Z logs the temperature measurements simultaneously byte after
byte in the datalog memory as well as in histogram form in the histogram memory. The datalog memory
is able to store 2048 temperature values measured at equidistant time points. The first temperature value
of a mission is written to address location 1000h of the datalog memory, the second value to address
location 1001h and so on. Knowing the starting time point (Mission Time Stamp), the interval between
temperature measurements, the Mission Samples Counter, and the rollover setting, one can reconstruct
the time and date of each measurement stored in the datalog.
There are two alternatives to the way the DS1921H/Z will behave after the 2048 bytes of datalog memory
is filled with data. With rollover disabled (RO = 0), the device will fill the datalog memory with the first
2048 mission samples. Additional mission samples are not logged in the datalog, but the histogram, and
temperature alarm memory continue to update. With rollover enabled (RO = 1), the datalog will wrap
around, and overwrite previous data starting at 1000h for the every 2049 th mission sample. In this mode
the device stores the last 2048 mission samples.
For the temperature histogram, the DS1921H/Z provides 64 bins that begin at memory address 0800h.
Each bin consists of a 16-bit, non-rolling-over binary counter that is incremented each time a temperature
value acquired during a mission falls into the range of the bin. The least significant byte of each bin is
stored at the lower address. Bin 0 begins at memory address 0800h, bin 1 at 0802h, and so on up to
087Eh for bin 63, as shown in Figure 7. The number of the bin to be updated after a temperature
conversion is determined by cutting off the two least significant bits of the binary temperature value. Out
of range values are range locked and counted as 00h or FFh.
12 of 45
相关PDF资料
PDF描述
DS1921K# KIT IBUTTON THERMOCHRON
DS1922E-F5# IBUTTON TEMP LOGGER 4KBit F5
DS1922L-F5# IBUTTON TEMP LOGGER
DS1923-F5# IBUTTON TEMP/HUMIDITY LOGGER F5
DS1961S-F3# IBUTTON EEPROM 1KBit F3
相关代理商/技术参数
参数描述
DS1921H-F5# 功能描述:iButton Thermochron High Res iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921H-F5/A1C 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921H-F5+A1C 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921H-F50 功能描述:iButton RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1921K 功能描述:存储器 IC 开发工具 RoHS:否 制造商:STMicroelectronics 产品:Reference Boards 工具用于评估:M24LR64-R 存储容量:64 kbit 存储类型:EEPROM 工作电源电压:1.8 V to 5.5 V