参数资料
型号: DS1922E-F5#
厂商: Maxim Integrated
文件页数: 15/44页
文件大小: 0K
描述: IBUTTON TEMP LOGGER 4KBit F5
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
RoHS指令信息: IButton RoHS Compliance Plan
标准包装: 5
系列: iButton®
存储容量: 512B
存储器类型: NVSRAM(非易失 SRAM)
产品目录页面: 1431 (CN2011-ZH PDF)
DS1922E
iButton High-Temperature Logger with
8KB Data-Log Memory
Mission Control Register
ADDRESS
0213h
BIT 7
1
BIT 6
1
BIT 5
SUTA
BIT 4
RO
BIT 3
(X)
BIT 2
TLFS
BIT 1
0
BIT 0
ETL
Note: During a mission, there is only read access to this register. Bits 6 and 7 have no function. They always read 1 and cannot be
written to 0. Bits 1 and 3 control functions that are not available with the DS1922E. Bit 1 must be set to 0. Under this condition the
setting of bit 3 becomes a “don’t care.”
Mission Control
The DS1922E is set up for its operation by writing
appropriate data to its special function registers, which
are located in the two register pages. The settings in
the Mission Control register determine which format (8
or 16 bits) applies and whether old data can be over-
written by new data once the data-log memory is full.
An additional control bit can be set to tell the DS1922E
to wait with logging data until a temperature alarm is
encountered.
Bit 5: Start Mission Upon Temperature Alarm
(SUTA). This bit specifies whether a mission begins
immediately (includes delayed start) or if a temperature
alarm is required to start the mission. If this bit is 1, the
device performs an 8-bit temperature conversion at the
selected sample rate and begins with data logging only
if an alarming temperature (high alarm or low alarm)
was found. The first logged temperature is when the
alarm occurred. However, the mission sample counter
does not increment. This functionality is guaranteed by
design and not production tested.
Maxim Integrated
Bit 4: Rollover Control (RO). This bit controls whether,
during a mission, the data-log memory is overwritten
with new data or whether data logging is stopped once
the data-log memory is full. Setting this bit to 1 enables
the rollover and data logging continues at the begin-
ning, overwriting previously collected data. If this bit is
0, the logging and conversions stop once the data-log
memory is full. However, the RTC continues to run and
the MIP bit remains set until the Stop Mission command
is performed.
Bit 2: Temperature Logging Format Selection
(TLFS). This bit specifies the format used to store tem-
perature readings in the data-log memory. If this bit is
0, the data is stored in 8-bit format. If this bit is 1, the
16-bit format is used (higher resolution). With 16-bit for-
mat, the most significant byte is stored at the lower
address.
Bit 0: Enable Temperature Logging (ETL). To set up
the device for a temperature-logging mission, this bit
must be set to logic 1. The recorded temperature val-
ues start at address 1000h.
15
相关PDF资料
PDF描述
DS1922L-F5# IBUTTON TEMP LOGGER
DS1923-F5# IBUTTON TEMP/HUMIDITY LOGGER F5
DS1961S-F3# IBUTTON EEPROM 1KBit F3
DS1963S-F5+ IBUTTON MONETARY SHA-1
DS1971-F3+ IBUTTON EEPROM 256KBIT F3
相关代理商/技术参数
参数描述
DS1922E-F5# 功能描述:iButton Temp Logger Ibutton w/8Kb Datalog Mem RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1922F-F5# 功能描述:iButton DS1922 RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1922L 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Temperature Logger iButton with 8KB Data-Log Memory
DS1922L_11 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Temperature Logger iButton with 8KB Data-Log Memory