参数资料
型号: DS1922E-F5#
厂商: Maxim Integrated
文件页数: 16/44页
文件大小: 0K
描述: IBUTTON TEMP LOGGER 4KBit F5
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
RoHS指令信息: IButton RoHS Compliance Plan
标准包装: 5
系列: iButton®
存储容量: 512B
存储器类型: NVSRAM(非易失 SRAM)
产品目录页面: 1431 (CN2011-ZH PDF)
DS1922E
iButton High-Temperature Logger with
8KB Data-Log Memory
Alarm Status Register
ADDRESS
0214h
BIT 7
BOR
BIT 6
1
BIT 5
1
BIT 4
1
BIT 3
0
BIT 2
0
BIT 1
THF
BIT 0
TLF
Note: There is only read access to this register. Bits 4 to 6 have no function. They always read 1. Bits 2 and 3 have no function with
the DS1922E. They always read 0. The alarm status bits are cleared simultaneously when the Clear Memory Function is invoked. See
memory and control functions for details.
General Status Register
ADDRESS
0215h
BIT 7
1
BIT 6
1
BIT 5
0
BIT 4
WFTA
BIT 3
MEMCLR
BIT 2
0
BIT 1
MIP
BIT 0
0
Note: There is only read access to this register. Bits 0, 2, 5, 6, and 7 have no function.
Alarm Status
The fastest way to determine whether a programmed
temperature threshold was exceeded during a mission
is through reading the Alarm Status register. In a net-
worked environment that contains multiple DS1922E
devices, the devices that encountered an alarm can
quickly be identified by means of the Conditional
Search command (see the 1-Wire ROM Function
Commands section). The temperature alarm only
occurs if enabled (see the Temperature Sensor Alarm
section). The BOR alarm is always enabled.
Bit 7: Battery-On Reset Alarm (BOR). If this bit reads
1, the device has performed a power-on reset. This
indicates that the device has experienced a shock big
enough to interrupt the internal battery power supply.
The device may still appear functional, but it has lost its
factory calibration. Any data found in the data-log
memory should be disregarded.
Bit 1: Temperature High Alarm Flag (THF). If this bit
reads 1, there was at least one temperature conversion
during a mission revealing a temperature equal to or
higher than the value in the Temperature High Alarm
register. A forced conversion can affect the THF bit.
This bit can also be set with the initial alarm in the
SUTA = 1 mode.
Bit 0: Temperature Low Alarm Flag (TLF). If this bit
reads 1, there was at least one temperature conversion
during a mission revealing a temperature equal to or
lower than the value in the Temperature Low Alarm reg-
ister. A forced conversion can affect the TLF bit. This
bit can also be set with the initial alarm in the SUTA = 1
mode.
16
General Status
The information in the General Status register tells the
host computer whether a mission-related command
was executed successfully. Individual status bits indi-
cate whether the DS1922E is performing a mission,
waiting for a temperature alarm to trigger the logging of
data or whether the data from the latest mission has
been cleared.
Bit 4: Waiting for Temperature Alarm (WFTA). If this
bit reads 1, the Mission Start Upon Temperature Alarm
was selected and the Start Mission command was suc-
cessfully executed, but the device has not yet experi-
enced the temperature alarm. This bit is cleared after a
temperature alarm event, but is not affected by the
Clear Memory command. Once set, WFTA remains set
if a mission is stopped before a temperature alarm
occurs. To clear WFTA manually before starting a new
mission, set the high temperature alarm (address
0209h) to +15°C and perform a forced conversion.
Bit 3: Memory Cleared (MEMCLR). If this bit reads 1,
the Mission Timestamp, mission samples counter, and
all the alarm flags of the Alarm Status register have
been cleared in preparation of a new mission.
Executing the Clear Memory command clears these
memory sections. The MEMCLR bit returns to 0 as soon
as a new mission is started by using the Start Mission
command. The memory must be cleared for a mission
to start.
Bit 1: Mission in Progress (MIP). If this bit reads 1,
the device has been set up for a mission and this mis-
sion is still in progress. The MIP bit returns from logic 1
to logic 0 when a mission is ended. See the Start
Mission and Stop Mission function commands.
Maxim Integrated
相关PDF资料
PDF描述
DS1922L-F5# IBUTTON TEMP LOGGER
DS1923-F5# IBUTTON TEMP/HUMIDITY LOGGER F5
DS1961S-F3# IBUTTON EEPROM 1KBit F3
DS1963S-F5+ IBUTTON MONETARY SHA-1
DS1971-F3+ IBUTTON EEPROM 256KBIT F3
相关代理商/技术参数
参数描述
DS1922E-F5# 功能描述:iButton Temp Logger Ibutton w/8Kb Datalog Mem RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1922F-F5# 功能描述:iButton DS1922 RoHS:否 存储类型:SRAM 存储容量:512 B 组织: 工作电源电压:3 V to 5.25 V 接口类型:1-Wire 最大工作温度:+ 85 C 尺寸:17.35 mm x 5.89 mm 封装 / 箱体:F5 MicroCan 制造商:Maxim Integrated
DS1922L 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Temperature Logger iButton with 8KB Data-Log Memory
DS1922L_11 制造商:MAXIM 制造商全称:Maxim Integrated Products 功能描述:Temperature Logger iButton with 8KB Data-Log Memory