MODEL
INPUT VOLTAGE
MAXIMUM INPUT
OUTPUT
RATED OUTPUT
RIPPLE & NOISE
TYPICAL
(VOLTS)
RANGE (VOLTS)
CURRENT (AMPS)*
VOLTAGE (VOLTS)
CURRENT (AMPS)
pk-pk (mV)
EFFICIENCY**
FRD512
5
4.65 - 5.50
2.01
±12
±0.23
40
65%
FRD515
5
4.65 - 5.50
2.04
±15
±0.19
40
66%
FRD1212
12
10.90 - 13.20
0.85
±12
±0.23
40
66%
FRD1215
12
10.90 - 13.20
0.86
±15
±0.19
40
67%
FRD2412
24
21.60 - 26.40
0.43
±12
±0.23
40
66%
FRD2415
24
21.60 - 26.40
0.45
±15
±0.19
40
65%
FRD2812
28
25.20 - 30.80
0.37
±12
±0.23
40
69%
FRD2815
28
25.20 - 30.80
0.38
±15
±0.19
40
71%
FRD4812
48
43.20 - 52.80
0.21
±12
±0.23
40
65%
FRD4815
48
43.20 - 52.80
0.22
±15
±0.19
40
66%
NOTES:
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Note: Current can be drawn from either output to its maximum value, or from both outputs to a combined total of 30 Watts.
1.40"
1.10"
0.800"
0.200"
0
(50.8mm)
2.00"
(50.8mm)
2.00"
0.18"(4.6mm) MIN.
0
5
4
2
1
3
(1.0mm)
DIA 0.040"
(10.2mm)
0.40"
0.500"
(12.7mm)
0.100"
(2.5mm)
-0.300"
(-7.6mm)
(35.6mm)
(20.3mm)
(5.1mm)
(27.9mm)
BOTTOM VIEW
Dual-Output, 5 Watts
FRD DC-DC Series Data Sheet
REV. JAN 31, 2006
Page 2 of 2
www.power-one.com
Model Selection
Mechanical Drawing
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Thermal Impedance
Natural convection
10.3 °C/W
100 LFM
7.7 °C/W
200 LFM
6.3 °C/W
300 LFM
5.1 °C/W
400 LFM
4.1 °C/W
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated
for specific application.
1+Vin
2-Vin
3+ Vout
4
Common
5- Vout
Pin
Function
Inches:
(Millimeters)
.XX ± 0.040
.X ± 1.0
.XXX ± 0.010
.XX ± 0.25
Pin:
± 0.002
± 0.05
Case:
+ 0.04, - 0.00
+ 1.0, - 0.0
(Tolerances as listed unless otherwise
specified.)
Tolerances
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.