参数资料
型号: HI7190IPZ
厂商: Intersil
文件页数: 2/25页
文件大小: 0K
描述: IC ADC 24BIT PROGBL SER 20-PDIP
产品培训模块: Solutions for Industrial Control Applications
标准包装: 18
位数: 24
数据接口: 串行,SPI?
转换器数目: 1
功率耗散(最大): 32.5mW
电压电源: 模拟和数字,双 ±
工作温度: -40°C ~ 85°C
安装类型: 通孔
封装/外壳: 20-DIP(0.300",7.62mm)
供应商设备封装: 20-PDIP
包装: 管件
输入数目和类型: 1 个差分,单极;1 个差分,双极
10
FN3612.10
June 27, 2006
SPI and Intel 8051 series SSR protocols. Data Integrity is
always maintained at the HI7190 output port. This means
that if a data read of conversion N is begun but not finished
before the next conversion (conversion N + 1) is complete,
the DRDY line remains active (low) and the data being read
is not overwritten.
The HI7190 provides many calibration modes that can be
initiated at any time by writing to the Control Register. The
device can perform system calibration where external
components are included with the HI7190 in the calibration
loop or self-calibration where only the HI7190 itself is in the
calibration loop. The On-chip Calibration Registers are
read/write registers which allow the user to read calibration
coefficients as well as write previously determined
calibration coefficients.
Circuit Operation
The analog and digital supplies and grounds are separate
on the HI7190 to minimize digital noise coupling into the
analog circuitry. Nominal supply voltages are AVDD = +5V,
DVDD = +5V, and AVSS = -5V. If the same supply is used
for AVDD and DVDD it is imperative that the supply is
separately decoupled to the AVDD and DVDD pins on the
HI7190. Separate analog and digital ground planes should
be maintained on the system board and the grounds should
be tied together back at the power supply.
When the HI7190 is powered up it needs to be reset by
pulling the RESET line low. The reset sets the internal
registers of the HI7190 as shown in Table 2 and puts the part
in the bipolar mode with a gain of 1 and offset binary coding.
The filter notch of the digital filter is set at 30Hz while the I/O
is set up for bidirectional I/O (data is read and written on the
SDIO line and SDO is three-stated), descending byte order,
and MSB first data format. A self calibration is performed
before the device begins converting. DRDY goes low when
valid data is available at the output.
The configuration of the HI7190 is changed by writing new
setup data to the Control Register. Whenever data is written
to byte 2 and/or byte 1 of the Control Register the part
assumes that a critical setup parameter is being changed
which means that DRDY goes high and the device is re-
synchronized. If the configuration is changed such that the
device is in any one of the calibration modes, a new
calibration is performed before normal conversions continue.
If the device is written to the conversion mode, a new
calibration is NOT performed (A new calibration is
recommended any time data is written to the Control
Register.). In either case, DRDY goes low when valid data is
available at the output.
If a single data byte is written to byte 0 of the Control
Register, the device assumes the gain has NOT been
changed. It is up to the user to re-calibrate the device if the
gain is changed in this manner. For this reason it is
recommended that the entire Control Register be written
when changing the gain of the device. This ensures that the
part is re-calibrated (if in a calibration mode) before the
DRDY output goes low indicating that valid data is available.
The calibration registers can be read via the serial interface
at any time. However, care must be taken when writing data
to the calibration registers. If the HI7190 is internally
updating any calibration register the user can not write to
that calibration register. See the Operational Modes section
for details on which calibration registers are updated for the
various modes.
Since access to the calibration registers is asynchronous to the
conversion process the user is cautioned that new calibration
data may not be used on the very next set of “valid” data after a
calibration register write. It is guaranteed that the new data will
take effect on the second set of output data. Non-calibrated
data can be obtained from the device by writing 000000 (h) to
the Offset Calibration Register, 800000 (h) to the Positive Full
Scale Calibration Register, and 800000 (h) to the Negative Full
Scale Calibration Register. This sets the offset correction factor
to 0 and the positive and negative gain slope factors to 1.
If several HI7190s share a system master clock the SYNC
pin can be used to synchronize their operation. A common
SYNC
input to multiple devices will synchronize operation
such that all output registers are updated simultaneously. Of
course the SYNC pin would normally be activated only after
each HI7190 has been calibrated or has had calibration
coefficients written to it.
The SYNC pin can also be used to control the HI7190 when
an external multiplexer is used with a single HI7190. The
SYNC
pin in this application can be used to guarantee a
maximum settling time of 3 conversion periods when
switching channels on the multiplexer.
Analog Section Description
Figure 6 shows a simplified block diagram of the analog
modulator front end of a sigma delta A/D Converter. The
input signal VIN comes into a summing junction (the PGIA in
this case) where the previous modulator output is subtracted
from it. The resulting signal is then integrated and the output
of the integrator goes into the comparator. The output of the
comparator is then fed back via a 1-bit DAC to the summing
TABLE 2. REGISTER RESET VALUES
REGISTER
VALUE (HEX)
Data Output Register
XXXX (Undefined)
Control Register
28B300
Offset Calibration Register
Self Calibration Value
Positive Full Scale Calibration Register
Self Calibration Value
Negative Full Scale Calibration Register
Self Calibration Value
HI7190
相关PDF资料
PDF描述
V24B48M250BF CONVERTER MOD DC/DC 48V 250W
MS27466E15A5S CONN RCPT 5POS WALL MT W/SCKT
V24B12M250BF3 CONVERTER MOD DC/DC 12V 250W
IDT72V255LA10PF IC FIFO SS 8192X18 10NS 64-TQFP
MS27497T10B99SA CONN RCPT 7POS WALL MNT W/SCKT
相关代理商/技术参数
参数描述
HI7191 制造商:INTERSIL 制造商全称:Intersil Corporation 功能描述:24-Bit, High Precision, Sigma Delta A/D Converter
HI7191_06 制造商:INTERSIL 制造商全称:Intersil Corporation 功能描述:24-Bit, High Precision, Sigma Delta A/D Converter
HI7191IB 功能描述:IC ADC 24BIT PROGBL SER 20-SOIC RoHS:否 类别:集成电路 (IC) >> 数据采集 - 模数转换器 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 位数:12 采样率(每秒):3M 数据接口:- 转换器数目:- 功率耗散(最大):- 电压电源:- 工作温度:- 安装类型:表面贴装 封装/外壳:SOT-23-6 供应商设备封装:SOT-23-6 包装:带卷 (TR) 输入数目和类型:-
HI7191IBZ 功能描述:模数转换器 - ADC ADC 24BIT SIGMADELTA 20 IND RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32
HI7191IBZ-T 功能描述:模数转换器 - ADC ADC 24BIT SIGMADELTA 20 IND RoHS:否 制造商:Texas Instruments 通道数量:2 结构:Sigma-Delta 转换速率:125 SPs to 8 KSPs 分辨率:24 bit 输入类型:Differential 信噪比:107 dB 接口类型:SPI 工作电源电压:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:VQFN-32