参数资料
型号: HMC660LC4B
厂商: HITTITE MICROWAVE CORP
元件分类: 放大器
英文描述: 20 MHz - 4500 MHz RF/MICROWAVE WIDE BAND LOW POWER AMPLIFIER
封装: 4 X 4 MM, ROHS COMPLIANT, SMT, 24 PIN
文件页数: 2/22页
文件大小: 763K
代理商: HMC660LC4B
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
T
R
A
C
K
-A
N
D
-HOL
D
-
SM
T
6
6 - 11
Linearity Measurement and Calculation
0.02 - 4.5 GHz WIDEBAND,
3 GS/s TRACK-AND-HOLD AMPLIFIER
v02.1208
HMC660LC4B
When characterizing the linearity of a T/H, the transfer function linearity of the held samples (referred to as T/H-mode
linearity) is usually the quantity of most interest to the user. These samples contain the signal information that is
ultimately digitized by the downstream A/D converter. Since the T/H-mode linearity is often different than the track-
mode linearity, this presents a unique measurement issue in that the linearity of only the hold-portion of the analog
output waveform must be selectively measured.
This issue is aggravated for high speed T/Hs because there are few wide-band time domain instruments (oscilloscopes
or A/D converters) with sufficient linearity to characterize a high linearity T/H. Therefore a frequency domain instrument
(spectrum analyzer) and measurement technique are used which allow selective characterization of the hold-mode
portion of the waveform
A common approach to this requirement has been to cascade two T/Hs in a dual rank configuration such that the
second T/H (T/H 2) re-samples the output of the first T/H (T/H 1). The two T/Hs are usually clocked 180 degrees out-
of-phase in master-slave operation to eliminate the track-mode portion of the output waveform from the first T/H. This
arrangement produces an output waveform that consists of two time segments. The first segment is the T/H 1 hold-
mode output as observed through the T/H 2 track-mode transfer function. The second time segment is the T/H 1 hold-
mode output re-sampled and held by the T/H 2 device. This measurement approach is not a perfect representation
of the linearity of a single T/H due to the impact of the second T/H on the overall linearity. However, it does eliminate
the track-mode portion of the T/H 1 output and permits a spectrum analyzer linearity measurement of the cascaded
devices. Since T/H 2 only has to sample the held waveform from T/H 1, the linearity impact of T/H 2 is primarily
associated with its DC linearity. An often used approximation is that the DC linearity of T/H 2 is much higher than the
slew-rate dependent, high frequency linearity of T/H 1 so that the total non-linearity of the cascade is dominated by
the high frequency linearity of T/H 1. In this case, the dual rank configuration has a net linearity that closely resembles
the linearity of a single T/H, particularly at high frequencies. However, this approximation is not always valid. If not, the
dual rank configuration fails to represent the linearity of a single T/H. The HMC660LC4B represents such a case; the
3rd order nonlinearity of this device varies relatively slowly with frequency and is high enough over the T/H bandwidth
that the DC linearity of the 2nd T/H significantly impacts the overall dual rank configuration.
Another linearity measurement issue unique to the T/H device is the need for output frequency response correction.
In the case of a dual rank T/H, the output waveform resembles a square wave with duration equal to the clock period.
Mathematically, the output can be viewed as the convolution of an ideal delta-function sample train with a single
square pulse of duration equal to one clock period. This weights the output spectral content with a SIN(πf/fs )/(πf/fs)
(Sinc) function frequency response envelope which has nulls at harmonics of the clock frequency fs and substantial
response reduction beyond half the clock frequency. The spectral content of the held samples without the envelope
weighting is required for proper measurement of the sample’s linearity. Either the impact of the response envelope
must be corrected in the data or a measurement method must be used that heterodynes the relevant nonlinear
harmonic products to low frequencies to avoid significant envelope response weighting. This latter method is referred
to as the beat-frequency technique.
The beat-frequency technique is commonly used for high-speed T/H linearity measurements, although the measurement
does impose restrictions on the specific input signal and clock frequencies that can be used. For example, with a
clock frequency of 512.5 MHz, a single tone input at 995 MHz beats with the 2nd harmonic of the sampling frequency
(through the sampling process) to produce a 1st order beat product at 30 MHz. Likewise, the 2nd and 3rd harmonics
of the input signal (generated via distortion in the T/H) beat with the 4th and 6th harmonics of the sampling frequency
respectively to produce 2nd and 3rd order beat products at 60 MHz and 90 MHz. In this manner, the T/H nonlinearity
in the vicinity of 1 GHz can be measured even though the 995 MHz fundamental and the 1.99 GHz and 2.985 GHz
nonlinear harmonics are well beyond the 206 MHz bandwidth of the Sinc response envelope.
The possible input frequency choices are overly limited when the low frequency beat-product technique is used at high
clock rates. A related high frequency beat-product measurement utilizing correction for the Sinc envelope weighting
must be employed to measure linearity over a wide range of input frequencies. Hittite uses both low frequency and
high frequency beat product methods to measure linearity for a wide range of clock and signal frequencies. Our high
frequency beat-product measurement avoids excessive envelope correction error by maintaining all beat products
within the 4 dB bandwidth of the Sinc function, where the envelope response is well behaved and easily modeled.
Hittite has also developed a method for accurately measuring the held-sample linearity of a single T/H using a beat-
frequency technique that avoids errors due to nonlinear products associated with the track-mode portion of the
相关PDF资料
PDF描述
HMC711LC5 17700 MHz - 23600 MHz RF/MICROWAVE DOUBLE BALANCED MIXER
HMC714LP5E 100 MHz - 5800 MHz RF/MICROWAVE LINEAR DETECTOR, 15 dBm INPUT POWER-MAX
HMC742LP5 70 MHz - 4000 MHz RF/MICROWAVE WIDE BAND MEDIUM POWER AMPLIFIER
HMC770LP4BE 40 MHz - 1000 MHz RF/MICROWAVE WIDE BAND MEDIUM POWER AMPLIFIER
HMC789ST89E 700 MHz - 2800 MHz RF/MICROWAVE WIDE BAND MEDIUM POWER AMPLIFIER
相关代理商/技术参数
参数描述
HMC660LC4B_09 制造商:HITTITE 制造商全称:Hittite Microwave Corporation 功能描述:0.02 - 4.5 GHz WIDEBAND, 3 GS/s TRACK-AND-HOLD AMPLIFIER
HMC661LC4B 制造商:Hittite Microwave Corp 功能描述:IC AMP TRACK&HOLD 4GS/S 24SMD
HMC662LP3 制造商:HITTITE 制造商全称:Hittite Microwave Corporation 功能描述:54 dB, LOGARITHMIC DETECTOR, 8 - 30 GHz
HMC662LP3_09 制造商:HITTITE 制造商全称:Hittite Microwave Corporation 功能描述:54 dB, LOGARITHMIC DETECTOR, 8 - 30 GHz
HMC662LP3E 制造商:Hittite Microwave Corp 功能描述:IC DETECTOR/CTLR LOG 54DB 16-QFN