参数资料
型号: IR3093M
厂商: International Rectifier
英文描述: 3 PHASE OPTERON, ATHLON, OR VR10.X CONTROL IC
中文描述: 3相皓龙,速龙,或控制IC的VR10.X
文件页数: 26/39页
文件大小: 693K
代理商: IR3093M
IR3093
Page 26 of 39
07/15/04
SETBIAS
FD
BIASOUT
I
SET
V
V
R
(15)
Compensation of the Current Share Loop
The crossover frequency of the current share loop should be at least one decade lower than that of the voltage
loop in order to eliminate the interaction between the two loops. A 22nF capacitor from SCOMP to LGND is good
for most of the applications. If necessary
have a 1k resistor in series with the Csc to make the current loop a little
bit faster.
Compensation of Voltage Loop
The adaptive voltage positioning is used in the computer applications to meet the load line requirements. Like
current mode control, the adaptive voltage positioning loop introduces extra zero to the voltage loop and splits the
double poles of the power stage, which make the voltage loop compensation much easier.
Resistors R
FB
and R
DRP
are chosen according to Equations (12) and (13), and the selection of compensation
types depends on the capacitors used. For the applications using Electrolytic, Polymer or AL-Polymer capacitors,
type II compensation shown in Figure 11 (a) is usually enough. While for the applications with only low ESR
ceramic capacitors, type III compensation shown in Figure 11 (b) is preferred.
(a) Type II compensation
(b) Type III compensation
Figure 11 . Voltage loop compensation network
Type II Compensation
Determine the compensation at no load, the worst case condition. Assume the time constant of the resistor and
capacitor across the output inductors matches that of the inductor, the crossover frequency of the voltage loop can
be estimated by Equations (16), where C
E
and R
CE
are the equivalent capacitance and ESR of output capacitors
respectively and R
LE
is the equivalent resistance of inductor DCR.
R
f
S
R
COMP
and C
COMP
have limited effect on the crossover frequency, and are used only to fine tune the crossover
frequency and transient load response. Choose the desired crossover frequency fc1 around fc estimated by
Equation (16) and determine R
COMP and
C
COMP.
)
*
(
*
2
CE
LE
FB
CS
E
DRP
R
C
R
R
G
C
(16)
CFB
CDRP
RCOMP
EAOUT
CCP1
CCOMP
RFB
RDRP
VO+
VDRP
VDAC
FB
+
-
EAOUT
RFB1
RCOMP
CCP1
EAOUT
CCOMP
RFB
RDRP
VO+
VDRP
VDAC
+
-
EAOUT
FB
相关PDF资料
PDF描述
IR3093MTR 3 PHASE OPTERON, ATHLON, OR VR10.X CONTROL IC
IR3080 XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT
IR3080MTR XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT
IR3080M XPHASE VRD10 CONTROL IC WITH VCCVID & OVERTEMP DETECT
IR3081 XPHASE VR 10.0 CONTROL IC
相关代理商/技术参数
参数描述
IR3093MPBF 功能描述:IC VID VOLTAGE PROGRAMMER 48MLPQ RoHS:是 类别:集成电路 (IC) >> PMIC - 电源控制器,监视器 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 应用:多相控制器 输入电压:- 电源电压:9 V ~ 14 V 电流 - 电源:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:40-WFQFN 裸露焊盘 供应商设备封装:40-TQFN-EP(5x5) 包装:带卷 (TR)
IR3093MTR 制造商:IRF 制造商全称:International Rectifier 功能描述:3 PHASE OPTERON, ATHLON, OR VR10.X CONTROL IC
IR3093MTRPBF 功能描述:IC CTLR 3PHASE VR10 48-MLQP RoHS:是 类别:集成电路 (IC) >> PMIC - 电源控制器,监视器 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:- 应用:多相控制器 输入电压:- 电源电压:9 V ~ 14 V 电流 - 电源:- 工作温度:-40°C ~ 85°C 安装类型:表面贴装 封装/外壳:40-WFQFN 裸露焊盘 供应商设备封装:40-TQFN-EP(5x5) 包装:带卷 (TR)
IR3094MPBF 功能描述:IC REG CTRLR BUCK PWM VM 48MLPQ RoHS:是 类别:集成电路 (IC) >> PMIC - 稳压器 - DC DC 切换控制器 系列:- 标准包装:4,000 系列:- PWM 型:电压模式 输出数:1 频率 - 最大:1.5MHz 占空比:66.7% 电源电压:4.75 V ~ 5.25 V 降压:是 升压:无 回扫:无 反相:无 倍增器:无 除法器:无 Cuk:无 隔离:无 工作温度:-40°C ~ 85°C 封装/外壳:40-VFQFN 裸露焊盘 包装:带卷 (TR)
IR3094MTRPBF 功能描述:开关变换器、稳压器与控制器 XPHASE VRD10 CTRL IC CTRL IC 200 to 700mV RoHS:否 制造商:Texas Instruments 输出电压:1.2 V to 10 V 输出电流:300 mA 输出功率: 输入电压:3 V to 17 V 开关频率:1 MHz 工作温度范围: 安装风格:SMD/SMT 封装 / 箱体:WSON-8 封装:Reel