参数资料
型号: ISL6740EVAL2
厂商: Intersil
文件页数: 13/28页
文件大小: 0K
描述: EVALUATION BOARD 2 ISL6740
标准包装: 1
主要目的: DC/DC,步降
输出及类型: 1,非隔离
功率 - 输出: 96W
输出电压: 12V
电流 - 输出: 8A
输入电压: 36 ~ 75 V
稳压器拓扑结构: 降压
板类型: 完全填充
已供物品:
已用 IC / 零件: ISL6740
ISL6740, ISL6741
The hysteresis voltage, Δ V, is:
sets a threshold that is compared to the voltage on the timing
? ? R1 + R3 ? ? ---------------------- ? ?
Δ V = 10
– 5
? R2 ?
R1 + R2
V
(EQ. 8)
capacitor, C T . The resistor divider percentage corresponds to the
fraction of the maximum duty cycle below which a short circuit
may exist. If the timing capacitor voltage fails to exceed the
Setting R3 equal to zero results in the minimum hysteresis, and
yields:
threshold before an overcurrent pulse is detected, a short circuit
condition exists. A shutdown and soft-start cycle will begin if 8
short circuit events occur within 32 oscillator cycles. Connecting
Δ V = 10
– 5
? R1
V
(EQ. 9)
SCSET to GND disables this feature.
Since the current sourced from both R TC and R TD determine the
charge and discharge currents for the timing capacitor, the effect
V IN ( UP ) = V IN ( DOWN ) + Δ V
As V IN increases from a UV condition, the threshold level is:
V (EQ. 10)
Overcurrent Operation
ISL6740 - Overcurrent delayed shutdown is enabled once the
soft-start cycle is complete. If an overcurrent condition is
detected, the soft-start charging current source is disabled and
the soft-start capacitor is allowed to discharge through a 15 μ A
source. At the same time a 50 μ s re-triggerable one-shot timer is
activated. It remains active for 50 μ s after the overcurrent
condition ceases. If the soft-start capacitor discharges by more
then 0.25V to 4.25V, the output is disabled and the Fault signal
asserted. This state continues until the soft-start voltage reaches
270mV, at which time a new soft-start cycle is initiated. If the
overcurrent condition stops at least 50 μ s prior to the soft-start
voltage reaching 4.25V, the soft-start charging currents revert to
normal operation and the soft-start voltage is allowed to recover.
The duration of the OC shutdown period can be increased by
adding a resistor between VREF and SS. The value of the resistor
must be large enough so that the minimum specified SS
discharge current is not exceeded. Using a 422k Ω resistor, for
example, will result in a small current being injected into SS,
effectively reducing the discharge current. This will increase the
OFF time by about 60%, nominally. The external pull-up resistor
will also decrease the SS duration, so its effect should be
considered when selecting the value of the SS capacitor.
Latching OC shutdown is also possible by using a lower valued
resistor between VREF and SS. If the SS node is not allowed to
discharge below the SS reset threshold, the IC will not recover
from an overcurrent fault. The value of the resistor must be low
enough so that the maximum specified discharge current is not
sufficient to pull SS below 0.33V. A 200k Ω resistor, for example,
prevents SS from discharging below ~0.4V. Again, the external
pull-up resistor will decrease the SS duration, so its effect should
be considered when selecting the value of the SS capacitor.
ISL6741 - Overcurrent results in pulse-by-pulse duty cycle
reduction as occurs in any peak current mode controller. This
results in a well controlled decrease in output voltage with
increasing current beyond the overcurrent threshold. An
overcurrent condition in the ISL6741 will not cause a shutdown.
Short Circuit Operation
A short circuit condition is defined as the simultaneous
occurrence of current limit and a reduced duty cycle. The degree
of reduced duty cycle is user adjustable using the SCSET input. A
resistor divider between either R TD or R TC and GND to RCSET
13
of the SCSET divider must be included in the timing calculations.
Typically the resistor between R TC and GND is formed by two
series resistors with the center node connected to SCSET.
Alternatively, SCSET may be set using a voltage between 0V and
2V. This voltage divided by 2 determines the percentage of the
maximum duty cycle that corresponds to a short circuit when
current limit is active. For example, if the maximum duty cycle is
95% and 1V is applied to SCSET, then the short circuit duty cycle
is 50% of 95% or 47.5%.
Fault Conditions
A fault condition occurs if V REF falls below 4.65V, the UV input
falls below 1.00V, the thermal protection is triggered, or if OTS
faults. When a fault is detected, OUTA and OUTB outputs are
disabled, the Fault signal is asserted, and the soft-start capacitor
is quickly discharged. When the fault condition clears and the
soft-start voltage is below the reset threshold, a soft-start cycle
begins. The Fault signal is high impedance during the soft-start
cycle.
An overcurrent condition that results in shutdown (ISL6740), or a
short circuit shutdown also cause assertion of the Fault signal.
The difference between a current fault and the faults described
earlier is that the soft-start capacitor is not quickly discharged.
The initiation of a new soft-start cycle is delayed while the soft-
start capacitor is discharged at a 15 μ A rate. This keeps the
average output current to a minimum.
Thermal Protection
Two methods of over-temperature protection are provided. The
first method is an on board temperature sensor that protects the
device should the junction temperature exceed 145 ° C. There is
approximately 15 ° C of hysteresis.
The second method uses an internal comparator with a 2.5V
reference (V REF /2). The non-inverting input to the comparator is
accessible through the OTS pin. A thermistor or thermal sensor
located at or near the area of interest may be connected to this
input. There is a nominal 25 μ A switched current source used to
create hysteresis. The current source is active only during an OT
fault; otherwise, it is inactive and does not affect the node
voltage. The magnitude of the hysteresis is a function of the
external resistor divider impedance. Either a positive
temperature coefficient (PTC) or a negative temperature
FN9111.6
December 2, 2011
相关PDF资料
PDF描述
VE-BTF-EX-S CONVERTER MOD DC/DC 72V 75W
VE-BTF-EW-S CONVERTER MOD DC/DC 72V 100W
ISL6405I2C-KIT-EVAL EVALUATION BOARD I2C ISL6405
ISL6405EVAL2 EVALUATION BOARD 2 ISL6405
VE-BT4-EY-F4 CONVERTER MOD DC/DC 48V 50W
相关代理商/技术参数
参数描述
ISL6740EVAL2Z 功能描述:EVALUATION BOARD 2 ISL6740 RoHS:是 类别:编程器,开发系统 >> 评估板 - DC/DC 与 AC/DC(离线)SMPS 系列:- 产品培训模块:Obsolescence Mitigation Program 标准包装:1 系列:True Shutdown™ 主要目的:DC/DC,步升 输出及类型:1,非隔离 功率 - 输出:- 输出电压:- 电流 - 输出:1A 输入电压:2.5 V ~ 5.5 V 稳压器拓扑结构:升压 频率 - 开关:3MHz 板类型:完全填充 已供物品:板 已用 IC / 零件:MAX8969
ISL6740EVAL3Z 制造商:Intersil Corporation 功能描述:ISL6740 EVALUATION BOARD 3 - ROHS COMPLIANT - SOIC - DSL - Bulk 制造商:Intersil Corporation 功能描述:Power Management IC Development Tools ISL6740 EVAL RD 3 ROHS CMPL DSL
ISL6740IB 功能描述:IC REG CTRLR PWM VM 16-SOIC RoHS:否 类别:集成电路 (IC) >> PMIC - 稳压器 - DC DC 切换控制器 系列:- 标准包装:2,500 系列:- PWM 型:电流模式 输出数:1 频率 - 最大:500kHz 占空比:100% 电源电压:8.2 V ~ 30 V 降压:无 升压:无 回扫:是 反相:无 倍增器:无 除法器:无 Cuk:无 隔离:是 工作温度:0°C ~ 70°C 封装/外壳:8-DIP(0.300",7.62mm) 包装:管件 产品目录页面:1316 (CN2011-ZH PDF)
ISL6740IB-T 功能描述:IC REG CTRLR PWM VM 16-SOIC RoHS:否 类别:集成电路 (IC) >> PMIC - 稳压器 - DC DC 切换控制器 系列:- 标准包装:2,500 系列:- PWM 型:电流模式 输出数:1 频率 - 最大:500kHz 占空比:100% 电源电压:8.2 V ~ 30 V 降压:无 升压:无 回扫:是 反相:无 倍增器:无 除法器:无 Cuk:无 隔离:是 工作温度:0°C ~ 70°C 封装/外壳:8-DIP(0.300",7.62mm) 包装:管件 产品目录页面:1316 (CN2011-ZH PDF)
ISL6740IBZ 功能描述:电压模式 PWM 控制器 VOLT PWM MODE CONTRL 16LD NSOIC RoHS:否 制造商:Texas Instruments 输出端数量:1 拓扑结构:Buck 输出电压:34 V 输出电流: 开关频率: 工作电源电压:4.5 V to 5.5 V 电源电流:600 uA 最大工作温度:+ 125 C 最小工作温度:- 40 C 封装 / 箱体:WSON-8 封装:Reel