参数资料
型号: LNXC2000
厂商: Red Lion Controls
文件页数: 1/8页
文件大小: 0K
描述: COUNTER DUAL PRESET 115VAC
标准包装: 1
系列: LYNX - LNXCC
计数速率: 50Hz
数字/字母数: 6
输入类型: 开关外壳或晶体管开关
输出类型: 接收器,晶体管
电源电压: 115VAC
显示器类型: LCD
其它名称: Q4894760
Bulletin No. LNXC1/2-D
Drawing No. LP0289
Released 5/03
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com
MODEL LNXC1 SINGLE PRESET COUNTER
MODEL LNXC2 DUAL PRESET COUNTER
!
!
!
!
!
!
!
!
!
!
!
!
!
!
0.3" (7.6 mm) HIGH, 6 DIGIT DISPLAY
NON-VOLATILE MEMORY (E 2 PROM)
DISPLAY SCROLLING (SELECTABLE)
BI-DIRECTIONAL COUNTING
PRESCALE CAPABILITY WITH DISABLE SWITCH (Dual Preset)
FORM C RELAY OUTPUT(S)
SOLID-STATE CURRENT SINKING OUTPUT(S)
PROGRAMMABLE TIMED OUTPUT(S)
REMOTE RESET CAPABILITY
ABILITY TO LOCK OUT FRONT PANEL FUNCTIONS
ACCEPTS INPUT COUNT RATES UP TO 15 KHz (Single preset)
AVAILABLE IN AC OR DC VERSIONS
FRONT PANEL PROGRAMMABLE DECIMAL POINT
SEALED FRONT PANEL CONSTRUCTION (NEMA 4X/IP65)
DESCRIPTION
The Lynx Series of presettable counters is an economical and reliable
solution to single or dual preset level requirements. The Model LNXC1 is the
single preset version and the Model LNXC2 is the dual preset version. Both
units have a solid-state output and a Form C relay output for each preset. These
units feature selectable input configurations, a full compliment of control
inputs, programmable timed outputs, prescale capability with disable switch
( dual preset only ), non-volatile memory, and many other features which will
satisfy most any single or dual preset application.
The Lynx Counters have two main counting actions, Reset to Zero (RTZ) and
Reset to Preset ( RTP ). There are eight modes of operation for the single preset
unit and sixteen for the dual preset unit.
All parameters are programmed through the front panel buttons. The Lynx
counters have an internal non-volatile memory device which eliminates the
need for battery back-up. When power is removed, this device will maintain all
data set-ups necessary for system operation. A Program Disable terminal is
provided, which can be used to prevent accidental changes or tampering by
unauthorized personnel to the preset(s), prescale or timed output values. The
front panel reset button can also be enabled or disabled by a rear panel DIP
switch. These counters also have an on-line self-test, which can be run at any
time without missing counts or missing a preset value.
Power, input, and output connections are made via removable terminal blocks
at the rear of the unit. The Lynx Series of counters have a sealed high impact
plastic bezel and meet NEMA 4X/IP65 specifications for wash-down and/or
dust, when properly installed.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use this unit to directly command motors, valves, or other actuators
not equipped with safeguards. To do so, can be potentially harmful to persons
or equipment in the event of a fault to the unit.
SPECIFICATIONS
1. DISPLAY : 6-digit, 0.3" (7.6 mm) high LCD display.
2. POWER REQUIREMENTS :
AC Power Versions : 115 VAC (±10%), 50/60 Hz, 6 VA
230 VAC (±10%), 50/60 Hz, 6 VA
DC Power Versions : 11 to 14 VDC @ 180 mA.
21.5 to 30 VDC @ 180 mA.
3. SENSOR POWER : +12 VDC (±25%) @ 100 mA.
4. COUNT INPUT : DIP switch selectable to accept count pulses from a variety
of sources, including switch contacts, outputs from CMOS or TTL circuits,
and all standard RLC sensors.
Current Sourcing : Unit provides 3.9 K ? pull-down load for sensors with
current sourcing outputs. (Max. input voltage, 28 VDC @ 7 mA.)
Current Sinking : Unit provides 7.8 K ? pull-up to +12 VDC for sensors
with current sinking outputs. (Max. sensor current, 1.6 mA.)
Debounce : Damping capacitor provided for switch contact debounce. Limits
count speed to 100 cps max. with 50% duty cycle.
Lo Bias : Input Trigger levels V IL = 1.5 V, V IH = 3.75 V
Hi Bias : Input Trigger levels V IL = 5.5 V, V IH = 7.5 V
CAUTION: Read complete instructions prior
to installation and operation of the unit.
CAUTION: Risk of electric shock.
Note : Bias levels ± 10% @ 12 VDC sensor voltage. These levels vary
proportionally with the sensor supply voltage.
5. PRESCALE VALUE RANGE : 0.00001 to 9.99999 (dual preset unit only).
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.7" (68.6)H x 4.0" (101.6)W.
PANEL CUT-OUT
1
相关PDF资料
PDF描述
LP-56-850 XFRMR 115/230V 28V 1.7A 48VA PCB
LS412460 DIODE MOD ISO SGL 2400V 600A
M4L-3-10 XFRMR 115V 8.7A 1000VA
M5060TB800 MODULE POWER 60A 800V 3PH BRIDGE
M81969/14-06 TOOL EXTRACTION #8 CONTACT PLAST
相关代理商/技术参数
参数描述
LNXCC000 制造商:Red Lion Controls 功能描述:CONTACT INPUT COUNTER
LNXEK-GK-519 制造商:GHI electronics 功能描述:Interface Development Tools FEZ Lynx Expandable Kit - Gadgeteer
LNY152C01 制造商:Panasonic Industrial Company 功能描述:LCD
LNY153C01 制造商:Panasonic Industrial Company 功能描述:LCD
LNY153C02 制造商:Panasonic Industrial Company 功能描述:DISPLAY