■ RELIABILITY DATA
*This catalog contains the typical specication only due to the limitation of space. When you consider the purchase of our products, please check our specication.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
11. Solderability
CM01
At least 90% of terminal electrode is covered by new solder.
CM04RC
At least 75% of terminal electrode is covered by new solder.
BU05MC
【Test Method and Remarks】
CM01
CM04RC·BU05MC
Solder temperature
245±5℃
235±5℃
Duration
3±1sec.
2±0.5sec.
Immersion depth
-
Up to 0.5mm from terminal root
12. Resistance to solder Heat
CM01
Within the specied tolerance.
CM04RC
Refer to the individual specication.
BU05MC
【Test Method and Remarks】
CM01
CM04RC·BU05MC
Reow soldering
Preheating
: 150 to 180℃ 1 to 2min
Peak
: 255±5℃ 5sec.
230±5℃ 30~40sec.
Number of reow : Within 2 times
Preheating
: 100 to 150℃ 1 to 2min
Peak
: 230 to 240℃ within 5sec.
More than 200℃ within 40sec.
Number of reow : Within 2 times
Manual soldering
-
Solder temperature : 350±5℃
Duration : 3±1sec.
Recovery : 1 to 2hrs of recovery under the standard
condition after the test.
13. Thermal shock
CM01
Within the specied tolerance.
CM04RC
Refer to the individual specication.
BU05MC
【Test Method and Remarks】
Accoding to JIS C 0025
Conditions of 1 cycle
Step
Temperature (℃)
Time (min)
CM01
CM04RC·BU05MC
CM01
CM04RC·BU05MC
1
ー40±3℃
ー25±3℃
30±3
2
Room Temp.
3
85±2℃
85±3℃
30±3
4
Room Temp.
3
Number of cycle :
CM01
: 100 cycle
CM04RC·BU05MC : 10 cycle
Recovery : Recovery under the standard condition after removal from test chamber.
CM01
: Should be measured within 2 to 48hours.
CM04RC·BU05MC : Leave within 1 to 2 hours.
14. Loading under damp heat
CM01
Within the specied tolerance.
CM04RC
Refer to the individual specication.
BU05MC
【Test Method and Remarks】
CM01
CM04RC·BU05MC
Temperature
60±2℃
40±3℃
Humidity
90~95%RH
Applied current
Rated current
Duration
1000±24hrs
Recovery : Recovery under the standard condition after removal from test chamber.
CM01
: Should be measured within 2 to 48hours.
CM04RC·BU05MC : Leave within 1 to 2 hours.
15. High temperature life test
CM01
ー
CM04RC
Refer to the individual specication.
BU05MC
【Test Method and Remarks】
CM04RC·BU05MC
Temperature
85±3℃
Duration
1000±24hrs
Recovery : Recovery under the standard condition after removal from test chamber.
CM01
: Should be measured within 2 to 48hours.
CM04RC·BU05MC : Leave within 1 to 2 hours.
16. Low Temperature life Test
CM01
Within the specied tolerance.
CM04RC
Refer to the individual specication.
BU05MC
【Test Method and Remarks】
CM01
CM04RC·BU05MC
Temperature
-40±2℃
-40±3℃
Applied current
1000±24hrs
Recovery : Recovery under the standard condition after removal from test chamber.
CM01
: Should be measured within 2 to 48hours.
CM04RC·BU05MC : Leave within 1 to 2 hours.