Stopping and Starting the Oscillator
The oscillator may be stopped at any time. If the
device is going to spend a significant amount of
time on the shelf, the oscillator can be turned off to
minimize current drain on the battery. The STOP
Bit is the MSB of the seconds register. Setting it to
a ’1’ stops the oscillator. The M48T08/18 is
shipped from STMicroelectronics with the STOP
Bit set to a ’1.’ When reset to a ’0,’ the M48T08/18
oscillator starts within one second.
Calibrating the Clock
The M48T08/18 is driven by a quartz-controlled
oscillator with a nominal frequency of 32,768 Hz.
A typical M48T08/18 is accurate within 1 minute
per month at 25°C without calibration. The devices
are tested not to exceed ± 35 ppm (parts per mil-
lion) oscillator frequency error at 25°C, which
equates to about ±1.53 minutes per month. With
the calibration bits properly set, the accuracy of
each M48T08/18 improves to better than +1/–2
ppm at 25°C.
The oscillation rate of any crystal changes with
temperature. Figure 13, page 21 shows the fre-
quency error that can be expected at various tem-
peratures. Most clock chips compensate for
crystal frequency and temperature shift error with
cumbersome “trim” capacitors. The M48T08/18
design, however, employs periodic counter cor-
rection. The calibration circuit adds or subtracts
counts from the oscillator divider circuit at the di-
vide by 256 stage, as shown in Figure 14, page 21.
The number of times pulses are blanked (subtract-
ed, negative calibration) or split (added, positive
calibration) depends upon the value loaded into
the five-bit Calibration Byte found in the Control
Register. Adding counts speeds the clock up, sub-
tracting counts slows the clock down.
The Calibration Byte occupies the five lower order
bits in the Control register. This byte can be set to
represent any value between 0 and 31 in binary
form. The sixth bit is the Sign Bit; '1' indicates pos-
itive calibration, '0' indicates negative calibration.
Calibration occurs within a 64 minute cycle. The
first 62 minutes in the cycle may, once per minute,
have one second either shortened by 128 or
lengthened by 256 oscillator cycles. If a binary '1'
is loaded into the register, only the first 2 minutes
in the 64 minute cycle will be modified; if a binary
6 is loaded, the first 12 will be affected, and so on.
Therefore, each calibration step has the effect of
adding 512 or subtracting 256 oscillator cycles for
every 125,829,120 actual oscillator cycles; that is
+4.068 or –2.034 ppm of adjustment per calibra-
tion step in the calibration register. Assuming that
the oscillator is in fact running at exactly 32,768Hz,
each of the 31 increments in the Calibration Byte
would represent +10.7 or –5.35 seconds per
month which corresponds to a total range of +5.5
or –2.75 minutes per month.
Two methods are available for ascertaining how
much calibration a given M48T08/18 may require.
The first involves simply setting the clock, letting it
run for a month and comparing it to a known accu-
rate reference (like WWV broadcasts). While that
may seem crude, it allows the designer to give the
end user the ability to calibrate his clock as his en-
vironment may require, even after the final product
is packaged in a non-user serviceable enclosure.
All the designer has to do is provide a simple utility
that accesses the Calibration Byte.
The second approach is better suited to a manu-
facturing environment, and involves the use of
standard test equipment. When the Frequency
Test (FT) Bit, the seventh-most significant bit in
the Day Register, is set to a '1,' and the oscillator
is running at 32,768 Hz, the LSB (DQ0) of the Sec-
onds Register will toggle at 512 Hz. Any deviation
from 512 Hz indicates the degree and direction of
oscillator frequency shift at the test temperature.
For example, a reading of 512.01024 Hz would in-
dicate a +20 PPM oscillator frequency error, re-
quiring a –10 (WR001010) to be loaded into the
Calibration Byte for correction.
Note: Setting or changing the Calibration Byte
does not affect the Frequency Test output fre-
quency. The device must be selected and ad-
dresses must be stable at Address 1FF9h when
reading the 512 Hz on DQ0.
The FT Bit must be set using the same method
used to set the clock: using the WRITE Bit. The
LSB of the Seconds Register is monitored by hold-
ing the M48T08/18 in an extended READ of the
Seconds Register, but without having the READ
Bit set. The FT Bit MUST be reset to '0' for normal
clock operations to resume.
For more information on calibration, see the Appli-
cation Note AN934, “TIMEKEEPER Calibration.”
相关PDF资料
PDF描述
M48T254V-10ZA1 REAL TIME CLOCK, PBGA168
M48T513V-70CS1 0 TIMER(S), REAL TIME CLOCK, PDSO32
M48T513Y-85PL1 0 TIMER(S), REAL TIME CLOCK, DMA36
M48T558YMH1 0 TIMER(S), REAL TIME CLOCK, PDSO28
M48T558YMH1TR 0 TIMER(S), REAL TIME CLOCK, PDSO28
相关代理商/技术参数
参数描述
M48T18-150PC 制造商:STMicroelectronics 功能描述:SRAM TIMEKEEPER 64K 48T18 DIP28 制造商:STMicroelectronics 功能描述:IC, TIMEKEEPER, YY-MM-DD-dd, 8KX8, DIP28, Date Format:YY-MM-DD-dd, Clock Format:
M48T18-150PC 制造商:STMicroelectronics 功能描述:SRAM TIMEKEEPER 64K 48T18 DIP28
M48T18-150PC1 功能描述:实时时钟 64K (8Kx8) 150ns RoHS:否 制造商:Microchip Technology 功能:Clock, Calendar. Alarm RTC 总线接口:I2C 日期格式:DW:DM:M:Y 时间格式:HH:MM:SS RTC 存储容量:64 B 电源电压-最大:5.5 V 电源电压-最小:1.8 V 最大工作温度:+ 85 C 最小工作温度: 安装风格:Through Hole 封装 / 箱体:PDIP-8 封装:Tube
M48T18-150PC1E 制造商:STMICROELECTRONICS 制造商全称:STMicroelectronics 功能描述:64 Kbit 8Kb x 8 TIMEKEEPER SRAM
M48T18-150PC1F 制造商:STMICROELECTRONICS 制造商全称:STMicroelectronics 功能描述:64 Kbit 8Kb x 8 TIMEKEEPER SRAM