参数资料
型号: MAX1801EKA+T
厂商: Maxim Integrated Products
文件页数: 9/16页
文件大小: 0K
描述: IC CNTRLR DC-DC SOT23-8
产品培训模块: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
标准包装: 2,500
应用: 控制器,数字式相机
输入电压: 2.7 V ~ 5.5 V
输出数: 1
工作温度: 0°C ~ 85°C
安装类型: 表面贴装
封装/外壳: SOT-23-8
供应商设备封装: SOT-23-8
包装: 带卷 (TR)
Digital Camera Step-Up Slave
DC-DC Controller
Switching Frequency
1.25
V DCON
V OSC (V)
D MAX =
t 2
t 1 + t 2
The MAX1801 switching frequency is set by the
MAX1800 or MAX1802 master converter (refer to the
appropriate data sheet for the design procedure).
Choose a switching frequency to optimize external
component size or efficiency for the particular
MAX1801 application. Typically, switching frequencies
between 400kHz and 500kHz offer a good balance
0.25
0
CLK
between component size and efficiency — higher fre-
quencies generally allow smaller components, and
lower frequencies give better conversion efficiency.
Setting the Output Voltages
Set the MAX1801 output voltage by connecting a resis-
tive voltage-divider from the output to FB as shown in
t 1
t 2
Figure 1. The FB input bias current is less than 100nA,
so choose R2 to be 100k ? to minimize the effect of
input bias current at FB. Choose R1 according to the
R 1 = R 2 ? OUT ? 1 ?
Figure 3. Setting the Maximum Duty Cycle
Shutdown
Set V DCON less than 0.35V to place the MAX1801 in
sleep mode, which drops the supply current to 5μA. To
reduce the supply current to 10nA, place the MAX1801
in shutdown by setting V REF below 0.4V. The MAX1801
enters soft-start when both V DCON and V REF are at nor-
mal levels.
Short-Circuit Protection
The MAX1801 has a fault protection feature that pre-
vents damage to transformer-coupled or SEPIC circuits
due to an output short circuit. If the output voltage
drops out of regulation, the voltage at COMP is
clamped at 2.7V. If this condition is maintained for 1024
oscillator clock periods at any time following soft-start,
the MAX1801 is disabled to prevent excessive output
relation:
? V ?
? V FB ?
where V FB is 1.25V, the regulation set point for the
MAX1801.
Setting the Maximum Duty Cycle
The master oscillator signal at OSC and the voltage at
DCON are used to generate the internal clock signal
(CLK in Figure 2). The internal clock ’ s falling edge
occurs when V OSC exceeds V DCON , the voltage at
DCON set by a resistive voltage-divider. The internal
clock ’ s rising edge occurs when V OSC falls below
0.25V (Figure 3). The maximum duty cycle can be
approximated by the equation:
( 1 ? f OSC FALL )
current. Restart the controller by cycling the voltage at
DCON or IN to GND and back to a normal state. For a
step-up application, short-circuit current is not limited,
D MAX =
R 4
R 3 + R 4
t
due to the DC current path through the inductor and
output rectifier to the short circuit. If short-circuit protec-
tion is required in a step-up configuration, a protection
device such as a fuse must be used to limit short-circuit
current.
Design Procedure
The MAX1801 can operate in a number of DC-DC con-
verter configurations, including step-up, SEPIC, and fly-
back. The following design discussions are limited to
the step-up configuration shown in Figure 1; SEPIC and
flyback examples are discussed in the Applications
Information section.
where f OSC and t FALL are the oscillator frequency (in
Hz) and the fall time (typically 100ns), respectively.
At 100kHz, the adjustable maximum duty-cycle range is
typically 28% to 92% (see Maximum Duty Cycle vs.
V DCON in the Typical Operating Characteristics ). The
maximum duty cycle typically defaults to 78% at 100kHz
if V DCON is at or above the voltage at V REF (1.25V), and
the controller shuts down if V DCON is less than 0.4V. If a
resistive voltage-divider is used at DCON, shut down the
MAX1801 by pulling DCON low with an open-drain sig-
nal from an external transistor. Drive DCON with appro-
priate logic levels to turn the MAX1801 on and off if the
default duty-cycle limit is used.
_______________________________________________________________________________________
9
相关PDF资料
PDF描述
MAX1802EHJ+ IC PWR SPLY STEP DOWN 32-TQFP
MAX1804EUB+ IC FEEDBACK INTERGRATOR 10UMAX
MAX1806EUA18+ IC REG LDO 1.8V/ADJ .5A 8-UMAX
MAX1809ETI+ IC DDR TERMINATION 28-TQFN
MAX1810ESA IC REG SMART CARD NETWORK 8-SOIC
相关代理商/技术参数
参数描述
MAX1802EHJ 功能描述:直流/直流开关转换器 Step-Up Slave DC/DC Controller RoHS:否 制造商:STMicroelectronics 最大输入电压:4.5 V 开关频率:1.5 MHz 输出电压:4.6 V 输出电流:250 mA 输出端数量:2 最大工作温度:+ 85 C 安装风格:SMD/SMT
MAX1802EHJ+ 功能描述:直流/直流开关转换器 Step-Up Slave DC/DC Controller RoHS:否 制造商:STMicroelectronics 最大输入电压:4.5 V 开关频率:1.5 MHz 输出电压:4.6 V 输出电流:250 mA 输出端数量:2 最大工作温度:+ 85 C 安装风格:SMD/SMT