参数资料
型号: MAX6656MEE+T
厂商: MAXIM INTEGRATED PRODUCTS INC
元件分类: 电源管理
英文描述: Dual Remote/Local Temperature Sensors and Four-Channel Voltage Monitors
中文描述: 4-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO16
封装: 0.150 INCH, 0.025 INCH PTICH, QSOP-16
文件页数: 17/18页
文件大小: 256K
代理商: MAX6656MEE+T
MAX6655/MAX6656
The temperature data is stored in internal registers
RRTE, RRT2, and RLTS as 7 bits + sign in two’s com-
plement form with each LSB representing 1°C.
Additionally, the 3MSBs of the Extended Temperature
register contain fractional temperature data with
+0.125°C resolution (Tables 2 and 3). The voltage data
is stored in RV0, RV1, RV2, and RV3 as 8 bits in binary
form (Table 4).
OVERT Output
OVERT output is an unlatched open-drain output that
behaves as a thermostat for fan control or system shut-
down (Figure 4). This output responds to the current
temperature. If the current temperature is above THIGH,
OVERT activates and does not go inactive until the tem-
perature drops below THIGH.
Diode Fault Alarm
A continuity fault detector at DXP detects whether the
remote diode has an open-circuit condition, short-cir-
cuit to GND, or short-circuit DXP-to-DXN condition. At
the beginning of each conversion, the diode fault is
checked, and the Status Byte is updated. This fault
detector is a simple voltage detector; if DXP rises
above VCC - 1V (typ) or below VDXN + 50mV (typ), a
fault is detected. Note that the diode fault isn’t checked
until a conversion is initiated, so immediately after POR,
the status byte indicates no fault is present, even if the
diode path is broken.
If the remote channel is shorted (DXP to DXN or DXP to
GND), the ADC reads 1111 1111 so as not to trip either
the THIGH or TLOW alarms at their POR settings.
Similarly, if DXP_ is short circuited to VCC, the ADC
reads -1°C for both remote channels, and the ALERT
outputs are activated.
Alert Interrupts
Normally, the ALERT interrupt output signal is latched
and can be cleared either by responding to the Alert
Response Address or by reading the Status register.
Interrupts are generated in response to THIGH and
TLOW, VHIGH and VLOW comparisons, and when the
remote diode is faulted. The interrupt does not halt auto-
matic conversions; new temperature data continues to
be available over the SMBus interface after ALERT is
asserted. The interrupt output pin is open-drain so multi-
ple devices can share a common interrupt line.
The interface responds to the SMBus Alert Response
address, an interrupt pointer return-address feature
(see the Alert Response Address section). Before tak-
ing corrective action, always check to ensure that an
interrupt is valid by reading the current temperature.
The alert activates only once per crossing of a given
temperature threshold to prevent any reentrant inter-
rupts. To enable a new interrupt, rewrite the value of the
violated temperature threshold.
Alert Response Address
The SMBus Alert Response interrupt pointer provides
quick fault identification for simple slave devices that lack
the complex, expensive logic needed to be a bus master.
Upon receiving an ALERT interrupt signal, the host mas-
ter can broadcast a Receive Byte transmission to the
Alert Response slave address (0001100). Any slave
device that generated an interrupt then attempts to identi-
fy itself by putting its own address on the bus (Table 5).
The Alert Response can activate several different slave
devices simultaneously, similar to the I2C General Call.
If more than one slave attempts to respond, bus arbitra-
tion rules apply, and the device with the lower address
code wins. The losing device does not generate an
acknowledgment and continues to hold the ALERT line
low until serviced (implies that the host interrupt input is
level sensitive). The alert is cleared after the slave
address is returned to the host.
Command Byte Functions
The 8-bit Command Byte register (Table 6) is the mas-
ter index that points to the other registers within the
MAX6655/MAX6656. The register’s POR state is 0000
0000, so a Receive Byte transmission (a protocol that
lacks the Command Byte) that occurs immediately after
POR returns the current internal temperature data.
Dual Remote/Local Temperature Sensors and
Four-Channel Voltage Monitors
8
_______________________________________________________________________________________
VCC
OVERT
MAX6655
MAX6656
SMBDATA
SMBCLK
ADD0
ADD1
GND
DXP2
DXN2
2200pF
2N3906
TO SYSTEM
SHUTDOWN
SMBus
SERIAL
INTERFACE
(TO HOST)
+3V TO +5.5V
ALERT
Figure 4. System Shutdown Application
相关PDF资料
PDF描述
MAX6657MSA+ ±1°C, SMBus-Compatible Remote/Local Temperature Sensors with Overtemperature Alarms
MAX6657MSA+T ±1°C, SMBus-Compatible Remote/Local Temperature Sensors with Overtemperature Alarms
MAX6658MSA+ ±1°C, SMBus-Compatible Remote/Local Temperature Sensors with Overtemperature Alarms
MAX6658MSA+T ±1°C, SMBus-Compatible Remote/Local Temperature Sensors with Overtemperature Alarms
MAX6660AEE+ Remote-Junction Temperature-Controlled Fan-Speed Regulator with SMBus Interface
相关代理商/技术参数
参数描述
MAX6656MEE-TG05 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6657MSA 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6657MSA+ 功能描述:板上安装温度传感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6657MSA+T 功能描述:板上安装温度传感器 Remote/Local Temperature Sensor RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor
MAX6657MSA-T 功能描述:板上安装温度传感器 RoHS:否 制造商:Omron Electronics 输出类型:Digital 配置: 准确性:+/- 1.5 C, +/- 3 C 温度阈值: 数字输出 - 总线接口:2-Wire, I2C, SMBus 电源电压-最大:5.5 V 电源电压-最小:4.5 V 最大工作温度:+ 50 C 最小工作温度:0 C 关闭: 安装风格: 封装 / 箱体: 设备功能:Temperature and Humidity Sensor