MC14069UB
http://onsemi.com
3
ELECTRICAL CHARACTERISTICS (Voltages Referenced to VSS)
Symbo
VDD
– 55
_C
25
_C
125
_C
Characteristic
Symbo
l
VDD
Vdc
Min
Max
Min
Typ (4.)
Max
Min
Max
Unit
Output Voltage
“0” Level
Vin = VDD
VOL
5.0
10
15
—
0.05
—
0
0.05
—
0.05
Vdc
Vin = 0
“1” Level
VOH
5.0
10
15
4.95
9.95
14.95
—
4.95
9.95
14.95
5.0
10
15
—
4.95
9.95
14.95
—
Vdc
Input Voltage
“0” Level
(VO = 4.5 Vdc)
(VO = 9.0 Vdc)
(VO = 13.5 Vdc)
VIL
5.0
10
15
—
1.0
2.0
2.5
—
2.25
4.50
6.75
1.0
2.0
2.5
—
1.0
2.0
2.5
Vdc
“1” Level
(VO = 0.5 Vdc)
(VO = 1.0 Vdc)
(VO = 1.5 Vdc)
VIH
5.0
10
15
4.0
8.0
12.5
—
4.0
8.0
12.5
2.75
5.50
8.25
—
4.0
8.0
12.5
—
Vdc
Output Drive Current
(VOH = 2.5 Vdc)
Source
(VOH = 4.6 Vdc)
(VOH = 9.5 Vdc)
(VOH = 13.5 Vdc)
IOH
5.0
10
15
– 3.0
– 0.64
– 1.6
– 4.2
—
– 2.4
– 0.51
– 1.3
– 3.4
– 4.2
– 0.88
– 2.25
– 8.8
—
– 1.7
– 0.36
– 0.9
– 2.4
—
mAdc
(VOL = 0.4 Vdc)
Sink
(VOL = 0.5 Vdc)
(VOL = 1.5 Vdc)
IOL
5.0
10
15
0.64
1.6
4.2
—
0.51
1.3
3.4
0.88
2.25
8.8
—
0.36
0.9
2.4
—
mAdc
Input Current
Iin
15
—
± 0.1
—
±0.00001
± 0.1
—
± 1.0
Adc
Input Capacitance
(Vin = 0)
Cin
—
—
—
—
5.0
7.5
—
—
pF
Quiescent Current
(Per Package)
IDD
5.0
10
15
—
0.25
0.5
1.0
—
0.0005
0.0010
0.0015
0.25
0.5
1.0
—
7.5
15
30
Adc
Total Supply Current (5.) (6.)
(Dynamic plus Quiescent,
Per Gate) (CL = 50 pF)
IT
5.0
10
15
IT = (0.3 A/kHz) f + IDD/6
IT = (0.6 A/kHz) f + IDD/6
IT = (0.9 A/kHz) f + IDD/6
Adc
Output Rise and Fall Times (5.)
(CL = 50 pF)
tTLH, tTHL = (1.35 ns/pF) CL + 33 ns
tTLH, tTHL = (0.60 ns/pF) CL + 20 ns
tTLH, tTHL = (0.40 ns/pF) CL + 20 ns
tTLH,
tTHL
5.0
10
15
—
—
—
100
50
40
200
100
80
—
—
ns
Propagation Delay Times (5.)
(CL = 50 pF)
tPLH, tPHL = (0.90 ns/pF) CL + 20 ns
tPLH, tPHL = (0.36 ns/pF) CL + 22 ns
tPLH, tPHL = (0.26 ns/pF) CL + 17 ns
tPLH,
tPHL
5.0
10
15
—
—
—
65
40
30
125
75
55
—
—
ns
4. Data labelled “Typ” is not to be used for design purposes but is intended as an indication of the IC’s potential performance.
5. The formulas given are for the typical characteristics only at 25
_C.
6. To calculate total supply current at loads other than 50 pF:
IT(CL) = IT(50 pF) + (CL – 50) Vfk
where: IT is in A (per package), CL in pF, V = (VDD – VSS) in volts, f in kHz is input frequency, and k = 0.002.