Enhanced Serial Communications Interface (ESCI) Module
MC68HC08GR32A MC68HC08GR16A Data Sheet, Rev. 0
162
Freescale Semiconductor
ACLK — Arbiter Counter Clock Select Bit
This read/write bit selects the arbiter counter clock source. Reset clears ACLK.
1 = Arbiter counter is clocked with one quarter of the ESCI input clock generated by the ESCI
prescaler
0 = Arbiter counter is clocked with the bus clock divided by four
NOTE
For ACLK = 1, the arbiter input clock is driven from the ESCI prescaler. The
prescaler can be clocked by either the bus clock or CGMXCLK depending
on the state of the ESCIBDSRC bit in MOR2.
AFIN— Arbiter Bit Time Measurement Finish Flag
This read-only bit indicates bit time measurement has finished. Clear AFIN by writing any value to
SCIACTL. Reset clears AFIN.
1 = Bit time measurement has finished
0 = Bit time measurement not yet finished
ARUN— Arbiter Counter Running Flag
This read-only bit indicates the arbiter counter is running. Reset clears ARUN.
1 = Arbiter counter running
0 = Arbiter counter stopped
AROVFL— Arbiter Counter Overflow Bit
This read-only bit indicates an arbiter counter overflow. Clear AROVFL by writing any value to
SCIACTL. Writing 0s to AM1 and AM0 resets the counter keeps it in this idle state. Reset clears
AROVFL.
1 = Arbiter counter overflow has occurred
0 = No arbiter counter overflow has occurred
ARD8— Arbiter Counter MSB
This read-only bit is the MSB of the 9-bit arbiter counter. Clear ARD8 by writing any value to SCIACTL.
Reset clears ARD8.
13.9.2 ESCI Arbiter Data Register
ARD7–ARD0 — Arbiter Least Significant Counter Bits
These read-only bits are the eight LSBs of the 9-bit arbiter counter. Clear ARD7–ARD0 by writing any
value to SCIACTL. Writing 0s to AM1 and AM0 permanently resets the counter and keeps it in this idle
state. Reset clears ARD7–ARD0.
Address: $000B
Bit 7
654321
Bit 0
Read:
ARD7
ARD6
ARD5
ARD4
ARD3
ARD2
ARD1
ARD0
Write:
Reset:
00000000
= Unimplemented