MK2049-34
3.3 VOLT COMMUNICATIONS CLOCK VCXO PLL
VCXO AND SYNTHESIZER
IDT 3.3 VOLT COMMUNICATIONS CLOCK VCXO PLL
6
MK2049-34
REV F 102203
External Component Selection
The MK2049-34 requires a minimum number of external components for proper operation. Decoupling capacitors of 0.01
μF
must be connected between VDD and GND pins close to the chip (especially pins 4 and 7, 15 and 17), and 33
Ω series
terminating resistors should be used on clock outputs with traces longer than one inch (assuming 50
Ωtraces). The selection
of additional external components is described in the following sections.
Loop Filter
Information on how to configure the external loop filter, connected between pins CAP1 and CAP2, can be found at
www.idt.com/?app=calculators&source=support_menu.
Crystal Operation
The MK2049-34 operates by phase locking the input signal to a VCXO which consists of the recommended pullable VCXO
crystals and the integrated VCXO oscillator circuit on the MK2049. To achieve the best performance and reliability, the
layout guidelines shown on the previous page should be closely followed.
The frequency of oscillation of a quartz crystal is determined by its cut and by the load capacitors connected to it. The
MK2049 has variable load capacitors on-chip which “pull” or change the frequency of the crystal. External stray capacitance
must be kept to a minimum to ensure maximum pullability of the crystal. To achieve this, the layout should use short traces
between the MK2049 and the crystal.
For the VCXO to operate correctly, a pullable crystal must be used. For more information, including a list of approved
crystals, please refer to application note MAN05 on the IDT web site.
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the MK2049-34. These ratings, which are
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these
or any other conditions above those indicated in the operational sections of the specifications is not implied.
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical
parameters are guaranteed only over the recommended operating temperature range.
Recommended Operation Conditions
Item
Rating
Supply Voltage, VDD
7 V
All Inputs and Outputs
-0.5 V to VDD+0.5 V
Ambient Operating Temperature
-40 to +85
° C
Storage Temperature
-65 to +150
° C
Junction Temperature
175
° C
Soldering Temperature
250
° C
Parameter
Min.
Typ.
Max.
Units
Ambient Operating Temperature
-40
+85
° C
Power Supply Voltage (measured in respect to GND)
+3.15
+3.3
+3.45
V