参数资料
型号: NCV7341D21G
厂商: ON Semiconductor
文件页数: 17/18页
文件大小: 0K
描述: TXRX CAN HS LOW POWER 14SOIC
标准包装: 55
类型: 收发器
驱动器/接收器数: 1/1
规程: CAN
电源电压: 4.75 V ~ 5.25 V
安装类型: 表面贴装
封装/外壳: 14-SOIC(0.154",3.90mm 宽)
供应商设备封装: 14-SOIC
包装: 管件
NCV7341
http://onsemi.com
8
Table 4. INTERNAL FLAGS AND THEIR VISIBILITY
Internal Flag
Set Condition
Reset Condition
Visibility on Pin ERR
VCC/VIO Undervoltage
VCC < VCC(SLEEP) longer than tUV(VCC)
or VIO < VIO(SLEEP) longer than tUV(VIO)
At wakeup or powerup
No
VBAT Undervoltage
VBAT < VBAT(STB)
When VBAT recovers
No
Powerup
VBAT rises above VBAT(PWUP)
(VBAT connection to the transceiver)
When normal mode is
entered
In receiveonly mode. Not
going from normal mode
Wakeup
When remote or local wakeup is
detected
At powerup or when normal
mode is entered or when
VCC/VIO undervoltage flag is
set
Both on ERR and RxD (both
pulled to low). In
gotosleep, standby and
sleep mode.
Local Wakeup
When local wakeup is detected
(i.e.via pin WAKE)
At powerup or when leaving
normal mode
In normal mode before 4
consecutive dominant
symbols are sent. Then ERR
pin becomes High again
Failure
Pin TxD clamped low or
overtemperature
When entering normal mode
or when RxD is Low while
TxD is high (provided all
failures disappeared)
Overtemperature condition
observable in receiveonly
mode entered from normal
mode
Bus Failure
(NCV7341D20)
One of the bus lines shorted to ground
or supply during four consecutive
transmitted dominants
No bus line short (to ground
or supply) detected during
four consecutive dominant bit
transmissions
In normal mode
VCC/VIO Undervoltage Flag
The VCC/VIO undervoltage flag is set if VCC supply drops
below VCC(sleep) level for longer than tUV(VCC) or VIO
supply drops below VIO(sleep) level for longer than tUV(VIO).
If the flag is set, the transceiver enters sleep mode. After a
waiting time identical to the undervoltage detection times
tUV(VCC) and tUV(VIO), respectively, the flag can be reset
either by a valid wakeup request or when the powerup flag
is set. During this waiting time, the wakeup detection is
blocked.
VBAT Undervoltage Flag
The flag is set when VBAT supply drops below VBAT(STB)
level. The transceiver will enter the standby mode. The flag
is reset when VBAT supply recovers. The transceiver then
enters the mode defined by inputs STB and EN.
Powerup Flag
This flag is set when VBAT supply recovers after being
below VBAT(PWUP) level, which corresponds to a
connection of the transceiver to the battery. The VCC/VIO
undervoltage flag is cleared so that the transceiver cannot
enter the Gotosleep Mode, ensuring that INH Pin is high
and the external voltage regulators are activated at the
battery connection. In Receiveonly mode, the powerup
flag can be observed on the ERR Pin. The flag is reset when
Normal mode is entered.
Wakeup Flag
This flag is set when the transceiver detects a valid
wakeup request via the bus or via the WAKE Pin. Setting
the wakeup flag is blocked during the waiting time of the
VCC/VIO undervoltage flag. The wakeup flag is
immediately propagated to Pins ERR and RxD – provided
that supplies VCC and VIO are available. The wakeup flag
is reset at powerup or when VCC/VIO undervoltage occurs
or when Normal mode is entered.
Local wakeup Flag
This flag is set when a valid wakeup request through
WAKE Pin occurs. It can be observed on the ERR Pin in
normal mode. It can only be set when the powerup flag is
reset. The local wakeup flag is reset at powerup or at
leaving Normal mode.
Failure Flag
The failure flag is set in one of the following situations:
TxD Pin is Low (i.e. dominant is requested by the CAN
controller) for longer than tdom(TxD) Under this
condition, the transmitter is disabled so that a bus
lockup is avoided in case of an application failure
which would drive permanent dominant on the bus. The
transmitter remains disabled until the failure flag is
reset.
Overtemperature If the junction temperature reaches
TJ(SD), the transmitter is disabled in order to protect it
from overheating and the failure flag is set. The
transmitter remains disabled until the failure flag is
reset.
The failure flag is reset when Normal mode is entered or
when TxD pin is High while RxD pin is Low. In case of
overtemperature, the failure flag is observable on pin ERR.
Bus Failure Flag (NCV7341D20)
The transmitter of the NCV7341D20 device version
allows bus failure detection. During dominant bit
transmission, a short of the CANH or CANL line to ground
or supply (VCC, VBAT or other) is internally detected. If the
short circuit condition lasts for four consecutive dominant
相关PDF资料
PDF描述
VI-B20-MW-F1 CONVERTER MOD DC/DC 5V 100W
MS3102A32-6PX CONN RCPT 23POS BOX MNT W/PINS
VE-J3D-MX-F4 CONVERTER MOD DC/DC 85V 75W
VI-2WK-MX-F4 CONVERTER MOD DC/DC 40V 75W
VE-J3D-MX-F3 CONVERTER MOD DC/DC 85V 75W
相关代理商/技术参数
参数描述
NCV7341D21R2G 功能描述:网络控制器与处理器 IC HS LP CAN TRANSC. RoHS:否 制造商:Micrel 产品:Controller Area Network (CAN) 收发器数量: 数据速率: 电源电流(最大值):595 mA 最大工作温度:+ 85 C 安装风格:SMD/SMT 封装 / 箱体:PBGA-400 封装:Tray
NCV7342 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:High Speed Low Power CAN Transceiver
NCV7342D10R2G 制造商:ON Semiconductor 功能描述:HS LP CAN TRANSC (L-WU) - Tape and Reel 制造商:ON Semiconductor 功能描述:IC TXRX CAN SGL WIRE 制造商:ON Semiconductor 功能描述:REEL - HS LP CAN TRANSC (L-WU)
NCV7342D13R2G 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:High Speed Low Power CAN Transceiver
NCV7356 制造商:ONSEMI 制造商全称:ON Semiconductor 功能描述:Single Wire CAN Transceiver