参数资料
型号: OKR-T/6-W12-C
厂商: Murata Power Solutions Inc
文件页数: 10/11页
文件大小: 0K
描述: CONV DC/DC 6A 12VIN POL SIP
产品培训模块: Okami Series
特色产品: Okami? Series PoL Converters
标准包装: 360
系列: Okami™ OKR-T/6
类型: 非隔离(POL)
输出数: 1
电压 - 输入(最小): 4.5V
电压 - 输入(最大): 14V
Voltage - Output 1: 0.591 ~ 6 V
电流 - 输出(最大): 6A
电源(瓦) - 制造商系列: 30W
特点: 具有远程开/关功能
安装类型: 通孔
封装/外壳: 5-SIP 模块
尺寸/尺寸: 0.41" L x 0.30" W x 0.65" H(10.4mm x 7.6mm x 16.5mm)
包装: 托盘
效率: 95.5%
电源(瓦特)- 最大: 30W
产品目录页面: 2720 (CN2011-ZH PDF)
其它名称: 811-2179
OKR-T/6 Series
Adjustable Output 6-Amp SIP-mount DC/DC Converters
TECHNICAL NOTES
Input Fusing
Certain applications and/or safety agencies may require fuses at the inputs of
power conversion components. Fuses should also be used when there is the
possibility of sustained input voltage reversal which is not current-limited. For
greatest safely, we recommend a fast blow fuse installed in the ungrounded
input supply line.
The installer must observe all relevant safety standards and regulations. For
safety agency approvals, install the converter in compliance with the end-user
safety standard, i.e. IEC/EN/UL 60950-1.
Input Under-Voltage Shutdown and Start-Up Threshold
Under normal start-up conditions, converters will not begin to regulate properly
until the ramping-up input voltage exceeds and remains at the Start-Up
Threshold Voltage (see Speci?cations). Once operating, converters will not
turn off until the input voltage drops below the Under-Voltage Shutdown Limit.
Subsequent restart will not occur until the input voltage rises again above the
Start-Up Threshold. This built-in hysteresis prevents any unstable on/off opera-
tion at a single input voltage.
Users should be aware however of input sources near the Under-Voltage
Shutdown whose voltage decays as input current is consumed (such as
capacitor inputs), the converter shuts off and then restarts as the external
capacitor recharges. Such situations could oscillate. To prevent this, make
sure the operating input voltage is well above the UV Shutdown voltage AT ALL
TIMES.
Start-Up Time
Assuming that the output current is set at the rated maximum, the Vin to Vout
For best performance, we recommend installing a low-ESR capacitor
immediately adjacent to the converter’s input terminals. The capacitor should
be a ceramic type such as the Murata GRM32 series or a polymer type. Initial
suggested capacitor values are 10 to 22 μF, rated at twice the expected maxi-
mum input voltage. Make sure that the input terminals do not go below the
undervoltage shutdown voltage at all times. More input bulk capacitance may
be added in parallel (either electrolytic or tantalum) if needed.
Recommended Output Filtering
The converter will achieve its rated output ripple and noise with no additional
external capacitor. However, the user may install more external output capaci-
tance to reduce the ripple even further or for improved dynamic response.
Again, use low-ESR ceramic (Murata GRM32 series) or polymer capacitors.
Initial values of 10 to 47 μF may be tried, either single or multiple capacitors in
parallel. Mount these close to the converter. Measure the output ripple under
your load conditions.
Use only as much capacitance as required to achieve your ripple and noise
objectives. Excessive capacitance can make step load recovery sluggish or
possibly introduce instability. Do not exceed the maximum rated output capaci-
tance listed in the speci?cations.
Input Ripple Current and Output Noise
All models in this converter series are tested and speci?ed for input re?ected
ripple current and output noise using designated external input/output compo-
nents, circuits and layout as shown in the ?gures below. In the ?gure below,
the Cbus and Lbus components simulate a typical DC voltage bus. Please
note that the values of Cin, Lbus and Cbus will vary according to the speci?c
converter model.
Start-Up Time (see Speci?cations) is the time interval between the point when
the ramping input voltage crosses the Start-Up Threshold and the fully loaded
TO
OSCILLOSCOPE
CURRENT
regulated output voltage enters and remains within its speci?ed accuracy band.
Actual measured times will vary with input source impedance, external input
capacitance, input voltage slew rate and ?nal value of the input voltage as it
+
L BUS
PROBE
+VIN
appears at the converter.
These converters include a soft start circuit to moderate the duty cycle of its
V IN
+
C BUS
C IN
PWM controller at power up, thereby limiting the input inrush current.
The On/Off Remote Control interval from On command to Vout regulated
assumes that the converter already has its input voltage stabilized above the
Start-Up Threshold before the On command. The interval is measured from the
On command until the output enters and remains within its speci?ed accuracy
band. The speci?cation assumes that the output is fully loaded at maximum
rated current. Similar conditions apply to the On to Vout regulated speci?cation
such as external load capacitance and soft start circuitry.
Recommended Input Filtering
The user must assure that the input source has low AC impedance to provide
dynamic stability and that the input supply has little or no inductive content,
-VIN
C IN = 2 x 100μF, ESR < 700mΩ @ 100kHz
C BUS = 1000μF, ESR < 100mΩ @ 100kHz
L BUS = 1μH
Figure 4: Measuring Input Ripple Current
In the ?gure below, the two copper strips simulate real-world printed circuit
impedances between the power supply and its load. In order to minimize circuit
errors and standardize tests between units, scope measurements should be
made using BNC connectors or the probe ground should not exceed one half
inch and soldered directly to the test circuit.
including long distributed wiring to a remote power supply. The converter will
operate with no additional external capacitance if these conditions are met.
www.murata-ps.com/support
MDC_OKR-T/6-W12 Series.B03 Page 10 of 11
相关PDF资料
PDF描述
OKX-T/3-D12N-C DC-DC CONVRT 0.7525-5.5V 3A 5SIP
OKX-T/3-W5P-C DC-DC CONVRT 0.7525-3.6V 3A 5SIP
OKX-T/5-D12P-C DC-DC CONVRT 0.7525-5.5V 5A 5SIP
OKX-T/5-W5P-C DC-DC CONVRT 0.7525-3.6V 5A 5SIP
OKX2-T/16-D12P-C CONVERT DC/DC SIP 80W 0.75-5.5V
相关代理商/技术参数
参数描述
OKX 制造商:MURATA-PS 制造商全称:Murata Power Solutions Inc. 功能描述:Adjustable DOSA 10/16-Amp SIP DC/DC Converters
OKX2-T/10-D12N-C 功能描述:DC/DC转换器 12V 0.75-5.5Vout 10A Sequence Neg logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
OKX2-T/10-D12P-C 功能描述:DC/DC转换器 12V 0.75-5.5Vout 10A Sequence Pos logic RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
OKX2-T/10-W5N-C 功能描述:DC/DC转换器 5Vin .75-3.6Vout 10A RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
OKX2-T/10-W5NJ-C 功能描述:DC/DC转换器 5Vin .75-3.6Vout 10A RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸: