参数资料
型号: PAXLHV00
厂商: Red Lion Controls
文件页数: 5/8页
文件大小: 0K
描述: METER AC VOLT 3-DIGIT PNL MNT
产品目录绘图: PAX Lite Series
PAX Lite Series Cut Out
标准包装: 1
系列: PAX®LITE
类型: 伏特表
测量范围: 0 ~ 600VAC
显示器样式: 红色字符,黑色背景
显示器类型: LED
显示器正面尺寸: 3.80" L x 1.95" W(96.5 x 49.5mm)
显示器位数: 3
显示器位数 - 高度: 0.560"(14.22mm)
背光:
安装类型: 面板安装
端子: 端接块
电源电压: 115VAC,230 VAC
其它名称: RLC111
3.0 W IRING
THE
M ETER
WIRING OVERVIEW
All conductors should meet voltage and current ratings for each terminal. Also,
cabling should conform to appropriate standards of good installation, local codes
1
BLOCK DIAGRAM
and regulations. It is recommended that power supplied to the unit be protected
by a fuse or circuit breaker. As depicted in the drawing of the Model PAXLHV,
POWER
SUPPLY
+V
all connections are made on the terminal block located at the rear of the unit.
2
CALIBRATION
ADJUSTMENT
DISPLAY
COMMON
(NEUTRAL)
600VAC
(HOT)
5
8
WAVE
SHAPING
CIRCUIT
1M
The PAX Lite AC Voltage Monitor incorporates a built-in precision
voltage divider that provides direct measurement from 0 to 600 VAC.
EMC INSTALLATION GUIDELINES
Although this meter is designed with a high degree of immunity to
Electromagnetic Interference (EMI), proper installation and wiring methods
must be followed to ensure compatibility in each application. The type of the
electrical noise, source or coupling method into the meter may be different for
various installations. Cable length, routing and shield termination are very
important and can mean the difference between a successful or a troublesome
installation. Listed below are some EMC guidelines for successful installation
in an industrial environment.
1. The meter should be mounted in a metal enclosure, that is properly connected
to protective earth.
2. Use shielded (screened) cables for all Signal and Control inputs. The shield
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in order
of their effectiveness.
a. Connect the shield only at the panel where the meter is mounted to earth
ground (protective earth).
b. Connect the shield to earth ground at both ends of the cable, usually when
the noise source frequency is above 1 MHz.
c. Connect the shield to common of the meter and leave the other end of the
shield unconnected and insulated from earth ground.
3. Never run Signal or Control cables in the same conduit or raceway with AC
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be run in metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
3.1 POWER WIRING
Primary AC power is connected to terminal 1 and 2 (Marked AC Power,
located on the left-hand side of the terminal block) . For best results, the AC
power should be relatively “Clean” and within the specified ±10% variation
limit. Drawing power from heavily loaded circuits or from circuits that also
power loads that cycle on and off, should be avoided.
AC Power
Terminal 1: VAC
4. Signal or Control cables within an enclosure should be routed as far as possible
from contactors, control relays, transformers, and other noisy components.
5. In extremely high EMI environments, the use of external EMI suppression
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional protection.
Install line filters on the power input cable to the unit to suppress power line
interference. Install them near the power entry point of the enclosure. The
following EMI suppression devices (or equivalent) are recommended:
Ferrite Suppression Cores for signal and control cables:
Fair-Rite # 0443167251 (RLC #FCOR0000)
TDK # ZCAT3035-1330A
Steward #28B2029-0A0
Line Filters for input power cables:
Schaffner # FN610-1/07 (RLC #LFIL0000)
Schaffner # FN670-1.8/07
Corcom #1VB3
Corcom #1VR3
Note: Reference manufacturer's instructions when installing a line filter.
6. Long cable runs are more susceptible to EMI pickup than short cable runs.
Therefore, keep cable runs as short as possible.
3.2 INPUT SIGNAL WIRING
Input connections are made on terminal 5 and 8. When powering the
PAXLHV with the same voltage that is being measured, terminal 5 (COMM.)
should be connected to neutral for the most stable reading on the display. If an
unstable display results from measuring a voltage that is isolated from the supply
voltage, reversing the supply voltage connections may correct this condition.
Voltage Input
Terminal 5: Common
Terminal 2: VAC
1
2
Terminal 8: 600 VAC
115/230
5
8
V
600V MAX. AC
5
相关PDF资料
PDF描述
PAXLIA00 METER AC CURRENT 3 1/2-DIGIT
PAXLIT00 METER AC CURRENT 5A 3 1/2-DIGIT
PAXLPV00 METER PROCESS VOLT 3 1/2-DIGIT
PAXLRT00 METER RTD TEMP 4-DIGIT
PAXLSG00 METER STRAIN GAGE 3 1/2-DIGIT
相关代理商/技术参数
参数描述
PAXLIA00 功能描述:METER AC CURRENT 3 1/2-DIGIT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLID00 功能描述:METER DC CURRENT 3 1/2-DIGIT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLIT00 功能描述:METER AC CURRENT 5A 3 1/2-DIGIT RoHS:是 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030
PAXLPT00 功能描述:METER PROCESS TIME 6-DIGIT RoHS:是 类别:工业控制,仪表 >> 定时器 系列:PAX®LITE 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
PAXLPV00 功能描述:METER PROCESS VOLT 3 1/2-DIGIT RoHS:否 类别:工业控制,仪表 >> 仪表 - 面板,数字 系列:PAX®LITE 标准包装:12 系列:* 其它名称:Q7072030