参数资料
型号: PKR4117ASI
厂商: ERICSSON POWER MODULES AB
元件分类: 电源模块
英文描述: 1-OUTPUT 15 W DC-DC REG PWR SUPPLY MODULE
封装: ROHS COMPLIANT, SMD-18
文件页数: 16/30页
文件大小: 1444K
代理商: PKR4117ASI
EYINGJI
3/1301-BMR 640 1411+ Uen
Approved
Checked
Date
Rev
Reference
SEC/D (Julia You)
EJANLLI
2009-4-10
F
Thermal Consideration continued
Definition of reference temperature (Tref)
The reference temperature is used to monitor the temperature
limits of the product. Temperatures above maximum Tref are
not allowed and may cause degradation or permanent
damage to the product. Tref is also used to define the
temperature range for normal operating conditions.
Tref is defined by the design and used to guarantee safety
margins, proper operation and high reliability of the module.
Ambient Temperature Calculation
By using the thermal resistance the maximum allowed
ambient temperature can be calculated.
1. The power loss is calculated by using the formula
((1/
η) - 1) × output power = power losses (Pd).
η = efficiency of converter. E.g. 80 % = 0.8
2. Find the thermal resistance (Rth) in the Thermal Resistance
graph found in the Output section for each model.
Calculate the temperature increase (ΔT).
ΔT = Rth x Pd
3. Max allowed ambient temperature is:
Max Tref - ΔT.
E.g. PKR 4910A at 1m/s:
1. ((
) -
1) × 9.9 W = 2.4 W
2. 2.4 W × 13.6°C/W = 33.7°C
3. 110 °C — 33.7°C = max ambient temperature is 77.3°C
The actual temperature will be dependent on several factors
such as the PCB size, number of layers and direction of
airflow.
Connections
1
9
2
3
4
5
6
7
8
18
17
16
15
14
13
12
11
10
Pin
Designation
Function
1
Out 1
Output 1
2
Rtn
Output return
3
Out 2
2)
Output 2
4
NC
Not connected
5
NC
Not connected
6
NC
Not connected
7
Sync
Synchronization input
8
Vadj
Output voltage adjust
9
NOR
Connection of Nominal Output
voltage Resistor1)
10
TOA
Turn-on/off input voltage adjust
11
RC
Remote control. Used to turn-
on/off output
12
NC
Not connected
13
NC
Not connected
14
NC
Not connected
15
NC
Not connected
16
NC
Not connected
17
- In
Negative Input
18
+ In
Positive input
1) Nominal voltage when pin 8 & 9 are connected together.
2) Only for duals.
1
0.8
E
PKR 4000A PI
DC/DC Converters, Input 36-75 V, 3 A / 15 W
EN/LZT 146 300 R5F April 2009
Ericsson AB
Technical Specication
23
相关PDF资料
PDF描述
PKR4928ASI 2-OUTPUT 9.5 W DC-DC REG PWR SUPPLY MODULE
PKR4221API 2-OUTPUT 15 W DC-DC REG PWR SUPPLY MODULE
PKR4910API 1-OUTPUT 9.9 W DC-DC REG PWR SUPPLY MODULE
PKR4928API 2-OUTPUT 9.5 W DC-DC REG PWR SUPPLY MODULE
PKR4117ASPBI 1-OUTPUT 15 W DC-DC REG PWR SUPPLY MODULE
相关代理商/技术参数
参数描述
PKR4117ASIA 制造商:Ericsson 功能描述:
PKR4128BPIA 制造商:Ericsson 功能描述:
PKR4128BPIC 制造商:Ericsson 功能描述:
PKR4128BSI 功能描述:DC/DC转换器 3.3 5Vdc Isolated Input 36-75V 13W RoHS:否 制造商:Murata 产品: 输出功率: 输入电压范围:3.6 V to 5.5 V 输入电压(标称): 输出端数量:1 输出电压(通道 1):3.3 V 输出电流(通道 1):600 mA 输出电压(通道 2): 输出电流(通道 2): 安装风格:SMD/SMT 封装 / 箱体尺寸:
PKR4128BSIA 制造商:Ericsson 功能描述: