ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
PACKAGE SPECIFICATIONS
SLTS284E – AUGUST 2007 – REVISED APRIL 2009 ....................................................................................................................................................... www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
ORDERING INFORMATION
For the most current package and ordering information, see the Package Option Addendum at the end of this datasheet, or see
the TI website at www.ti.com.
over operating free-air temperature range unless otherwise noted
(1)
UNIT
TA
Operating free-air temperature
Over VI range
-40 to 85
°C
Surface temperature of module body or pins
Twave
Wave solder temperature
260 (2)
(5 seconds maximum)
Tstg
Storage temperature
Storage temperature of module removed from shipping
-55 to 125
package
Tpkg
Packaging temperature
Shipping Tray storage or bake temperature
45
(1)
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2)
This product is not compatible with surface-mount reflow solder processes.
MIN
MAX
UNIT
VI
Input voltage
4.5
14
V
TA
Operating free-air temperature
–40
85
°C
PTR08100W
UNIT
Weight
2.74 grams
Flammability
Meets UL 94 V-O
Mechanical shock
Per Mil-STD-883D, Method 2002.3, 1 msec, 1/2 sine, mounted
250 G (1)
Mechanical vibration
Mil-STD-883D, Method 2007.2, 20-2000 Hz
5 G (1)
(1)
Qualification limit.
2
Copyright 2007–2009, Texas Instruments Incorporated