ENGINEERING DATA SHEET
SERIES F470
RAILWAY RELAY
4 PDT, 1 AMP / 72VDC
APPLICATION NOTES:
APPLICABLE SOCKET:
Polarized, non latching, hermetically sealed relay
Contact arrangement
4 PDT
Coil supply
Direct current
Meets the requiements of
MIL-R-6106
CEECC16101-019
NF F 62-002-2 FP n°9
PRINCIPLE TECHNICAL CHARACTERISTICS
Contact rating
72 Vdc / 1 Amp
Weight
< 80 grams
Dimensions of can without
hardware
26mm x 25.7mm x 26mm max
Balanced-force design.
Tin plated, hermetically sealed metal can.
Non-overlapping contact arrangement, see note 5 page 4.
CONTACT ELECTRICAL CHARACTERISTICS
Nominal contact
voltage (Vdc)
Contact rating in Amps
Level
Minimum
operating cycles
resistive load
inductive load (L/R=30ms)
72 V
5
≤ U ≤ 90 V
15
≤ U ≤ 35 V
35
< U ≤ 90 V
90
< U ≤ 140 V
1
1 to 20mA
-
0.6
-
10 mA to 1.50 Amps
10 mA to 0.50 Amps
10 mA to 0.35 Amps
High level
Low level
High level
1,000,000 cycles
2,000,000 cycles
2,000,000
cycles
Life expectancy for DC loads other than 72Vdc: See application note n°003
Featuring LEACH power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue: 4/06
- 13 -
Page 1 of 4