Parameter
Test Conditions
Min.
Typ.
Max.
Unit
V
A
mA
pF
C
A
nsec
C
A
nsec
°C/W
°C
nH
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk
SML60SUZ06S
Document Number 2431
Issue 1
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is
believed to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in
its use. Semelab encourages customers to verify that datasheets are current before placing orders.
VF
Forward Voltage Drop
IR
Leakage Current
CT
Junction Capacitance
Qrr
Reverse Recovery Charge
Irr
Reverse Recovery Current
trr
Reverse Recovery Time
Qrr
Reverse Recovery Charge
Irr
Reverse Recovery Current
trr
Reverse Recovery Time
trr
Reverse Recovery Time
IF = 60A
Tj = 25°C
IF = 60A
Tj = 125°C
IF = 30A
Tj = 25°C
VR = 600V
Tj = 25°C
VR = 600V
Tj = 125°C
VR = 200V
Tj = 25°C
VR = 300V
IF = 60A
di / dt = 800A/sTJ = 25°C
VR = 300V
IF = 60A
di / dt = 800A/sTJ = 125°C
VR = 50V
IF = 1A
di / dt = 100A/sTJ = 25°C
1.65
2.25
1.7
1.35
1.2
400
0.75
5
81
1.53
34
90
2.98
51
117
50
0.6
300
10
ELECTRICAL CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
STATIC ELECTRICAL CHARACTERISTIC
DYNAMIC ELECTRICAL CHARACTERISTIC
THERMAL AND MECHANICAL CHARACTERISTICS
Rθjc
Junction to Case Thermal Resistance
TL
Lead Temperature
LS
Stray Inductance
15.85 (0.624)
16.05 (0.632)
1.00 (.039)
1.15 (.045)
4.90 (0.193)
5.10 (0.201)
1.45 (0.057)
1.60 (0.063)
5.45 (.215) BSC
2 plcs.
0.020 (0.001)
0.250 (0.010)
1.20 (.047)
1.40 (.083)
13.30 (0.524)
13.60 (0.535)
0.40 (.016)
0.65 (.026)
1.15 (.045)
1.45 (.057)
1.90 (.075)
2.10 (.083)
2.70 (.106)
2.90 (.114)
18.70 (.736)
19.10 (.752)
Cathode
1 - Cathode
2 - Anode
2.40 (.094)
2.70 (.106)
12.40 (.488)
12.70 (.500)
(Base of Lead)
Heat Sink (Cathode)
and Leads are Plated
12
Dimensions in mm(inches)
D3PAK Package