参数资料
型号: ST16C654IJ68-F
厂商: Exar Corporation
文件页数: 8/51页
文件大小: 0K
描述: IC UART FIFO 64B QUAD 68PLCC
标准包装: 19
特点: *
通道数: 4,QUART
FIFO's: 64 字节
规程: RS232
电源电压: 2.97 V ~ 5.5 V
带自动流量控制功能:
带IrDA 编码器/解码器:
带故障启动位检测功能:
带调制解调器控制功能:
带CMOS:
安装类型: 表面贴装
封装/外壳: 68-LCC(J 形引线)
供应商设备封装: 68-PLCC
包装: 管件
其它名称: 1016-1272
ST16C654/654D
xr
2.97V TO 5.5V QUAD UART WITH 64-BYTE FIFO
REV. 5.0.2
16
2.11
Auto RTS Hardware Flow Control
Automatic RTS hardware flow control is used to prevent data overrun to the local receiver FIFO. The RTS#
output is used to request remote unit to suspend/resume data transmission. The auto RTS flow control
features is enabled to fit specific application requirement (see Figure 11):
Enable auto RTS flow control using EFR bit-6.
The auto RTS function must be started by asserting RTS# output pin (MCR bit-1 to logic 1 after it is enabled).
If needed, the RTS interrupt can be enabled through IER bit-6 (after setting EFR bit-4). The UART issues an
interrupt when the RTS# pin makes a transition from low to high: ISR bit-5 will be set to logic 1.
2.12
Auto CTS Flow Control
Automatic CTS flow control is used to prevent data overrun to the remote receiver FIFO. The CTS# input is
monitored to suspend/restart the local transmitter. The auto CTS flow control feature is selected to fit specific
application requirement (see Figure 11):
Enable auto CTS flow control using EFR bit-7.
If needed, the CTS interrupt can be enabled through IER bit-7 (after setting EFR bit-4). The UART issues an
interrupt when the CTS# pin is de-asserted (logic 1): ISR bit-5 will be set to 1, and UART will suspend
transmission as soon as the stop bit of the character in process is shifted out. Transmission is resumed after
the CTS# input is re-asserted (logic 0), indicating more data may be sent.
FIGURE 10. RECEIVER OPERATION IN FIFO AND AUTO RTS FLOW CONTROL MODE
Receive Data Shift
Register (RSR)
RXFIFO1
16X Clock
E
rror
T
ags
(64-
sets)
E
rro
rTa
gs
in
LSR
b
its
4
:2
64 bytes by 11-bit
wide
FIFO
Receive Data Characters
FIFO
Trigger=16
Example
:
- RX FIFO trigger level selected at 16 bytes
Data fills to
56
Data falls to
8
Data Bit
Validation
Receive
Data FIFO
Receive
Data
Receive Data
Byte and Errors
RHR Interrupt (ISR bit-2) programmed for
desired FIFO trigger level.
FIFO is Enabled by FCR bit-0=1
RTS# de-asserts when data fills above the flow
control trigger level to suspend remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
RTS# re-asserts when data falls below the flow
control trigger level to restart remote transmitter.
Enable by EFR bit-6=1, MCR bit-1.
相关PDF资料
PDF描述
VE-B74-IW-F2 CONVERTER MOD DC/DC 48V 100W
ST16C654CJ68-F IC UART FIFO 64B QUAD 68PLCC
VE-B73-IX-F4 CONVERTER MOD DC/DC 24V 75W
XR17V252IM-F IC UART PCI BUS DUAL 100TQFP
MS3110E14-15S CONN RCPT 15POS WALL MNT W/SCKT
相关代理商/技术参数
参数描述
ST16C654IJ68-F 制造商:Exar Corporation 功能描述:IC QUAD UART 1.5MBPS 5.5V 68-PLCC
ST16C654IJ68TR-F 制造商:Exar Corporation 功能描述:UART 4-CH 64Byte FIFO 3.3V/5V 68-Pin PLCC T/R 制造商:Exar Corporation 功能描述:2.97V to 5.5V Quad UART with 64 Byte FIFOs PLCC 68 制造商:Exar Corporation 功能描述:ST16C654IJ68TR-F
ST16C654IQ 制造商:Exar Corporation 功能描述:
ST16C654IQ100 制造商:EXAR 制造商全称:EXAR 功能描述:QUAD UART WITH 64-BYTE FIFO AND INFRARED (IrDA) ENCODER/DECODER
ST16C654IQ100-F 功能描述:UART 接口集成电路 QUAD UARTW/64BYTE FIFO RoHS:否 制造商:Texas Instruments 通道数量:2 数据速率:3 Mbps 电源电压-最大:3.6 V 电源电压-最小:2.7 V 电源电流:20 mA 最大工作温度:+ 85 C 最小工作温度:- 40 C 封装 / 箱体:LQFP-48 封装:Reel