Z-Power
LED
X10490
Z-Power
LED
X10490
Technical
Data
Sheet
Rev. 1.00
December 2009
www.acriche.com
Document No. : SSC-QP-7-07-24 (Rev.00)
11. Precaution for Use
(1) Storage conditions
Keep the product in a dry box or a desiccator with a desiccant in order to prevent
moisture absorption.
a.
Keep it at a temperature in the range from 5°Cto 30°C and at a humidity of less
than 50% RH.
In case of being stored for more than 3 months, the product should be sealed with
Nitrogen gas.
(2) After opening the package .
When soldering, this could result in a decrease of the photoelectric effect or light
intensity.
a.
Soldering should be done right after mounting the product.
b.
Keep the temperature in the range from 5°Cto 30°C and the humidity at less
than 30%.
Soldering should be done within 7 days after opening the desiccant package.
If the product has been exposed for more than 7 days after opening the package or
the indicating color of the desiccator changes, the product must be baked at a
temperature between 65 ± 5°C for 10 to 24 hours.
An unused and unsealed product should be repacked in a desiccant package and kept
sealed in a dry atmosphere.
(3) Precautions for use
Any external mechanical force or excessive vibration should not be applied to the
product during cooling after soldering, and it is preferable to avoid rapid cooling.
The product should not be mounted on a distorted part of PCB.
Gloves or wrist bands for ESD(Electric Static Discharge) should be wore in order to
prevent ESD and surge damage, and all devices and equipments must be grounded to
the earth.
(4) Miscellaneous
Radiation resistance is not considered.
When cleaning the product, any kind of fluid such as water, oil and organic solvent
must not be used and IPA(Isopropyl Alcohol) must be used.
When using the product, operating current should be settled in consideration of the
maximum ambient temperature.
Its appearance or specification for improvement is subject to change without notice.