Filter specification
TFS 341
4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
pre-heating periods
main-heating periods
peak temperature
Temperature: 150 °C - 170 °C
over 200 °C
240 °C ± 5 °C
Time:
110 sec. - 140 sec.
60 sec. - 65 sec.
Possible chip-mount air reflow profile
0
20
40
60
80
100
120
140
160
180
200
220
240
260
10 30 50 70 90 110 130 150 170 190 210 230 250 270 290 310 330 350 370 390
time / sec.
temperature
/°C
Table for temperature vs. time for the given air reflow profile
Tolerance of temperatures: ± 5 °C
time / sec.
temperature / °C
time / sec.
temperature / °C
time / sec.
temperature / °C
0
21
140
153
280
182
10
21
150
155
290
189
20
25
160
157
300
200
30
41
170
159
310
205
40
80
180
161
320
208
50
109
190
162
330
211
60
124
200
163
340
213
70
134
210
164
350
213
80
141
220
166
360
210
90
147
230
168
370
203
100
150
240
171
380
188
110
153
250
173
390
168
120
153
260
176
130
153
270
178
www.vectron.com
USA: Vectron International 166 Glover Avenue, Norwalk, CT 06856 Tel: 1-88-VECTRON-1 Fax: 1-888-FAX-VECTRON
EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44(0) 1703 766 288 Fax: 44 (0) 1703 766 822
In Austria, Belgium, France, Germany, Luxembourg, Netherlands, Sweden, Switzerland: Tel: 49 (0) 72 63 648 0 Fax: 49(0) 72 63 125
ASIA: In China, Taiwan, Japan: Tel: 1-603-598-0075 In Korea, Singapore, Australia, India: Tel: 1-203-853-4433 Fax: 1-203-849-1423
Vectron International reserves the right to make changes to the product(s) and/or information contained herein without notice.
No liability is assumed as a result of their use or application.
No rights under any patent accompany the sale of any such product(s) or information.