Filename: tfs 869a.doc
Version 1.2
04.05.2004
VI TELEFILTER
Filter specification
TFS 869A
1/5
Tele Filter GmbH
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Measurement condition
Ambient temperature:
23
°C
Input power level:
0 dBm
Terminating impedances:
input: 50
output: 50
Characteristics
Remark:
The maximum of the pass band attenuation amax is defined as the insertion loss ae. The nominal frequency fN is fixed at 869,0 MHz without tolerance. The
given values for the absolute attenuation ae have to be reached at the frequencies given below even if the centre frequency fc is shifted due to the
temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fc.
D a t a
typ. value
tolerance / limit
Insertion Loss
ae
1,8
dB
3,0
dB
Nominal Frequency
fN
-
869,0
MHz
Centre Frequency
fC
869,0
MHz
-
Passband
PB
fN
± 1,0
MHz
Absolute Attenuation
arel
fN -
1,0 MHz ... fN +
1,0 MHz
1,8
dB
max.
3
dB
fN ±
20
MHz … fN ±
23,0 MHz
42
dB
min.
35
dB
fN ±
41
MHz … fN ±
44
MHz
42
dB
min.
40
dB
Operating Temperature Range
OTR
-
- 30 °C ... + 80 °C
Storage Temperature Range
-
- 40 °C ... + 85 °C
Temperature Coefficient of Frequency
TCf **
- 36
ppm/K
-
Input Power Level
-
max.
17
dBm
**)
f(Hz) = TCf(ppm/K) x (T-T0) x fTo(MHz).