![](http://datasheet.mmic.net.cn/120000/TPB-5-5-15-1-D24_datasheet_3424121/TPB-5-5-15-1-D24_3.png)
TPB Models
25-40W , TRIPLE
OUTPUT
DC/DC
CONVER TERS
3
Performance/Functional Specifications
Typical @ TA = +25°C under nominal line voltage and "full-load" conditions, unless noted.
Input
InputVoltage Range:
Q12 Models
10-36 Volts (24V nominal)
D24 Models
18-36 Volts (24V nominal)
Q48 Models
18-72 Volts (48V nominal)
D48 Models
36-72 Volts (48V nominal)
Input Current
See Ordering Guide
Input FilterType
Pi
Overvoltage Shutdown:
Q12 and D24 Models
40 Volts
Q48 and D48 Models
80 Volts
Reverse-Polarity Protection
Yes (Instantaneous, 6A maximum)
On/Off Control (Pin 5)
TTL high (or open) = on, low = off
Output
VOUT Accuracy (50% load):
+5V Output
±1%
±12V or ±15V Outputs
±3%
Temperature Coefficient
±0.02% per °C
Ripple/Noise (20MHz BW)
See Ordering Guide
Line/Load Regulation
See Ordering Guide
Efficiency
See Ordering Guide
Isolation Voltage
750Vdc, minimum
Isolation Capacitance
500pF
Current Limiting
Continuous, auto-recovery
Overvoltage Protection
Zener/transorb clamps, magnetic fdbk.
Dynamic Characteristics
Transient Response (50% load step)
300sec max. to ±3% of final value
Switching Frequency
125kHz (±10%)
Environmental
OperatingTemperature (ambient):
Without Derating
–25 to +50°C (Model dependent)
With Derating
to +95°C
Maximum Baseplate Temperature
+95°C
Storage Temperature
–40 to +105°C
Physical
Dimensions
2" x 3" x 0.5" (50.8 x 76.2 x 12.7mm)
Shielding
6-sided
Case Connection
Pin 4
Case Material
Bright tin-plated steel
Baseplate Material
Aluminum
Pin Material
Brass, solder coated
Weight
4 ounces (113 grams)
These converters require a minimum 10% loading on their primary output and 20% loading
on each auxiliary output to maintain specified regulation. Operation under no-load conditions
will not damage these devices; however they may not meet all listed specifications.
"Full load" varies by part number and is determined by the input voltage range as indicated by
the part number suffix. See Technical Notes and Output Power Considerations.
Application-specific input/output filtering can be recommended or perhaps added internally
upon request. Contact DATEL Applications Engineering for details.
Applying a voltage to the On/Off Control pin when no input power is applied to the converter
can cause permanent damage to the converter. If desired, the On/Off Control function can be
replaced with a Sync function. See page 6 of this data sheet for more details.
Filtering and Noise Reduction
All TPB 25-40 Watt DC/DC Converters achieve their rated ripple and noise
specifications without the use of external input/output capacitors. In critical
applications, input/output ripple and noise may be further reduced by
installing electrolytic capacitors across the input terminals and/or low-ESR
tantalum or electrolytic capacitors across the output terminals. Output
capacitors should be connected between their respective output pin (pin 6, 7
or 9) and Common (pin 8). The caps should be located as close to the
power converters as possible. See Figure 7. Typical values are listed in the
tables below. In many applications, using values greater than those listed
will yield better results.
To Reduce Input Ripple
Q12, D24 Models
47F, 50V
Q48, D48 Models
10F, 100V
To Reduce Output Ripple
+5V Output
47F, 10V, Low ESR
±12/15V Outputs
22F, 20V, Low ESR
In critical, space-sensitive applications, DATEL may be able to tailor the
internal input/output filtering of these devices to meet your specific require-
ments. Contact our Applications Engineering Group for additional details.
Input Fusing
Certain applications and/or safety agencies may require the installation of fuses
at the inputs of power conversion components. For DATEL TPB
DC/DC Converters, you should use slow-blow type fuses with values no
greater than the following:
VIN Range
FuseValue
Q12
4A
D24
4A
Q48
3A
D48
2A
InputVoltage:
Q12/D24 Models
44 Volts
Q48/D48 Models
88 Volts
Input Reverse-Polarity Protection
Current must be <6A. Brief
duration only. Fusing recommended.
Output Overvoltage Protection
+5V Output
6.8 Volts, limited duration
±12V Outputs
15 Volts, limited duration
±15V Outputs
18 Volts, limited duration
Output Current
Current limited. Max. current and
short-circuit duration are model
dependent.
Storage Temperature
–40 to +105°C
Lead Temperature (soldering, 10 sec.)
+300°C
These are stress ratings. Exposure of devices to any of these conditions may adversely
affect long-term reliability. Proper operation under conditions other than those listed in the
Performance/Functional Specifications Table is not implied.
Absolute Maximum Ratings
TECHNICAL NO TES