TPS2014, TPS2015
POWER DISTRIBUTION SWITCHES
SLVS159C DECEMBER 1996 REVISED MARCH 2004
4
TI.COM
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Input voltage range, VI (see Note1)
0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, VO (see Note1)
0.3 V to VI(IN) + 0.3 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, VI at EN
0.3 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, IO
internally limited
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation
See Dissipation Rating Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature range, TJ
0
°C to 125°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg
65
°C to 150°C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds
260
°C
. . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to GND.
DISSIPATION RATING TABLE
PACKAGE
TA ≤ 25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C
TA = 70°C
POWER RATING
TA = 125°C
POWER RATING
P
1175 mW
9.4 mW/
°C
752 mW
235 mW
D
725 mW
5.8 mW/
°C
464 mW
145 mW
recommended operating conditions
MIN
MAX
UNIT
Input voltage, VI
4
5.5
V
Input voltage, VI at EN
0
5.5
V
Continuous output current, IO
TPS2014
0
0.6
A
Continuous output current, IO
TPS2015
0
1
A
Operating virtual junction temperature, TJ
0
125
°C
electrical characteristics over recommended operating junction temperature range, VI(IN)= 5.5 V,
IO = rated current, EN = 0 V (unless otherwise noted)
power switch
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VI = 5.5 V,
TJ = 25°C
75
95
ron
On-state resistance
VI = 5 V,
TJ = 25°C
80
95
m
ron
On-state resistance
VI = 4.5V,
TJ = 25°C
90
110
m
VI = 4 V,
TJ = 25°C
96
110
Ilkg
Leakage current, output
EN = VI,
TJ = 25°C
0.001
1
A
Ilkg
Leakage current, output
EN = VI,
0
°C ≤ TJ ≤ 125°C
10
A
tr
Rise time, output
VI = 5.5 V,
TJ = 25°C
CL = 1 F
4
ms
tr
Rise time, output
VI = 4 V,
TJ = 25°C
CL = 1 F
3.8
ms
tf
Fall time, output
VI = 5.5 V,
TJ = 25°C
CL = 1 F
3.9
ms
tf
Fall time, output
VI = 4 V,
TJ = 25°C
CL = 1 F
3.5
ms
Pulse-testing techniques maintain junction temperature close to ambient temperature; thermal effects must be taken into account separately.